UniEquip Benchtop Autoclaves
'CertoClav' Personal
Sterilisers, 12 and 18 litre, top loading
The economical choice for basic, benchtop sterilising
Features:
- Temperature range: 125°C in 15 min. (1.4 bar) & 140°Cin 3 min. (2.7 bar)
- Made of aluminium
- 2-step valve
- Thermometer
- Precision manometer with maximum indicator
- Safety lock (no opening under pressure)
- Steam release valve and steam release cock
- Anti-block safety valve
- Safety standard approved
- Heater included
Specifications:
|
Model |
CV-EL 12L |
CV-EL 18L |
|
Volume |
12 litre |
18 litre |
|
Weight |
6.1 Kg. |
7.7 Kg. |
|
Chamber diameter |
240 mm. |
240 mm. |
|
Chamber height |
260 mm. |
400 mm. |
Ordering information:
|
8511 |
CertoClav model CV-EL 12L autoclave, 12 litre |
|
8512 |
CertoClav model CV-EL 18L autoclave, 18 litre |
|
Accessories |
|
|
85.810.10 |
Instrument holder complete with 6 suspension hooks and 2 handles for safe removal of sterilised material |
|
85.820.10 |
Instrument basket with tripod, complete with 2 handles |
|
85.850.00 |
Condensation lid, complete with felt insert (for use only with 85.810.10 or 85.820.10) |
|
86.700.24 |
Instrument tray |
|
12.503.96 |
Tripod, to be used in conjunction with 86.700.24 |
SA Series Horizontal Benchtop
Autoclaves, 16 and 24 litre
Features:
- Class B - CE and TÜV certified or Class S - CE certified, ISO 9001
- 16 or 24 litre chamber capacities
- Sterilisation temperature 121°C / 135°C
- Intelligent design for your professional choice
- Microprocessor temperature control system
- 24 installed programmes and special programmes for PRION sterilisation, liquid sterilisation and test programmes; fully automatic processing
- Auto-fill water system
- Door lock indication
- Digital temperature display
- Analogue vacuum gauge
Specifications:
|
Model |
SA-260MA |
SA-230MA |
|
Auto dry time can be selected, 0, 15, 30, 35, 40 minutes |
Yes |
Yes |
|
Ext.dimensions: D x W x H mm. |
655 x 533 x 442 |
594 x 522 x 410 |
|
Capacity of water tank |
4.2 litre |
4.2 litre |
|
Chamber capacity |
24 litre |
16 litre |
|
Weight, Kg. |
52 |
49 |
|
Power supply |
230V 50/60Hz |
230V 50/60Hz |
|
Power consumption |
2400W / 11 Amp. |
1900W / 8 Amp. |
|
Safety devices |
||
|
Pressure safety valve & protection switch |
Yes |
Yes |
|
Over temperature protection |
Yes |
Yes |
|
Water tank water level sensor |
Yes |
Yes |
|
Pressure door auto-lock |
Yes |
Yes |
|
Standard accessories |
Sterilisation box, Tray, 3 piece, holder |
Sterilisation box, tray, 3 piece, holder |
|
Optional accessories |
Sterilisation plate set |
Sterilisation plate set |
Ordering information:
|
8413 |
SA-230FA benchtop autoclave, 16 litre, Class S (with CE) |
|
8414 |
SA-260FA, benchtop autoclave, 24 litre, Class S (with CE) |
|
8411 |
SA-230MA, benchtop autoclave, 16 litre, Class B (with CE & TÜV), with pre- and dry vacuum function |
|
8412 |
SA-260MA, benchtop autoclave, 24 litre, Class B (with CE & TÜV), with pre- and dry vacuum function |
'Microm' Series Benchtop Autoclaves
40 litre
Features:
- Automatic temperature control system (not 'pressure control') to give more stable and reliable sterilisation service
- Electronic microprocessor control. All the working programmes are set up in microprocessor system. Just push the selection button and 'Microm' will do the rest automatically, from add water to sterilisation and dry cycle
- Pressure door auto-lock device (door automatically locked when pressure > 0.3 Kg / cm²
- Working temperatures range from 121°C to 134°C
- Door unlocked warning: door lamp will light and stop all the functions if the door has not been locked completely
- Sterilisation cycle completion indicator: auto-check circuit system can double check the sterilisation programmes and if all are completed the cycle completion lamp will light up
- Emergency exhaust safety switch
- Low water alarm: 'low water' indicator lamp will light up, buzzer will sound and all functions will stop if chamber water or water reservoir are low
- Pre-heating programme by dry heater, which can not only keep the chamber temperature in balance, but also offers the perfect dry and sterilisation functions
Specifications:
|
Chamber capacity |
40 litre (SA-300H) |
|
Chamber dimensions |
SA-300H: 300 mm. dia. x 550 mm. deep (304 stainless steel) |
|
Ext. dimensions |
SA-300H: 600W x 470H x 740D mm. |
|
Power consumption |
240V / 2.1 Kw / 8.8A |
|
Operating temperature / pressure |
*SA-300H: 121 - 132°C / 2.1 Kg./cm.² * Wrapped: SA-252M: 121 - 134°C / 2.2 Kg./cm.² SA-300H: 121 - 132°C / 2.1 Kg./cm.² * Liquids: 121°C / 1.2 Kg./ cm.² (both models) |
|
Design temperature |
140°C |
|
Standard accessory |
1 x sterilisation box (304 stainless steel) + 1 x tray (SA-300H) |
|
Safety approval |
CE. EMC, LVD, by TÜV CE, MDD approved by DNV Chamber designed by ASME/USA Standard |
|
Auto-dry function |
Yes |
|
|
|
Ordering information:
|
|
|
|
8415 |
'Microm' model SA-300H, 40 litre |
'Falcon' Series, Class S, Benchtop
Autoclave, front loading, 24 litre
Features:
- Pressure door auto-lock device (SA-252F only). The door will be locked automatically when the pressure exceeds 0.3 Kg./cm²
- Pre-heating programme by dry heating to keep the chamber temperature in balance, to offer the perfect dry function and the best sterilisation function
- 'Falcon' Series autoclaves provide sterilisation temperatures from 121°C to 132°C which are suitable for wrapped / unwrapped materials, utensils, liquids, etc.
- Chamber made of 304 stainless steel
Specifications:
|
Model |
SA-252F |
|
Chamber dimensions |
260 mm. dia. x 450 mm. D |
|
Chamber capacity |
23.8 litre |
|
Overall dimensions |
540W x 450H x 630D mm. |
|
Power consumption |
240V / 2.1 kW / 8.8A |
|
Working temp. / pressure |
Unwrapped: 121-132°C / 2.1 Kg/cm² Wrapped: 121-132°C / 2.1 Kg/cm² Liquids: 121°C / 1.2 Kg/cm² |
|
Design temp. |
140°C |
|
Safety devices |
Pressure control switch; door pressure auto-lock; door safety catches; over-temp. protection; safety valve; electronic circuit safety system; emergency exhaust switch |
|
Auto-dry function |
Yes |
|
Standard accessories |
1 x stainless steel sterilisation box; 1 x heater cover |
|
Optional accessories |
Stainless steel tray frame; 3 x tray; 1 x tray pulling holder; 2 x stainless steel sterilisation spring holders |
Ordering information:
|
8418F |
'Falcon' model SA-252F, 24 litre |
'Poleax' Series, Class N, Benchtop
Autoclave, front loading, 16 litre
Features:
- Chamber made of 304 stainless steel and heater made of 316L stainless steel
- Sterilisation programmes are fully automatic and easy to control
- Choice of pre-selected programmes with sterilisation pressure adjustable from 0.9 to 2.1 Kg./cm² (approx. 115°C to 134°c). Selectable sterilisation times of 4, 15 or 30 minutes
- Automatic control from heating up to sterilisation to turn off
- The entire sterilisation process is continuously monitored by a microprocessor indication system
- The sterilisation time starts counting when the chamber pressure (temperature) reaches the set-up point
- Security and reliability: autoclave conforms to 93/42/EEC and is CE approved
- Over-heat (low water) level protection system
- Each element with independent thermostat protection switch
- Microprocessor system can indicate the programme working stops
- Poleax Series can be used for liquid sterilisation
Specifications:
|
Model |
SA-232X |
|
Chamber dimensions |
230 mm. dia. x 390 mm. D |
|
Chamber capacity |
16 litre |
|
Overall dimensions |
501W x 406H x 537D mm. |
|
Power consumption |
240V / 1.5 kW / 6.5A |
|
Working temp. / pressure |
Unwrapped / Wrapped / Liquids 115-134°C / 0.9 - 2.1 Kg/cm² |
|
Design temp. |
140°C |
|
Safety devices |
Over-heat (low water) cut-off switch; safety valve and release valve; emergency exhaust valve; pressure control switch |
|
Standard accessories |
1 x stainless steel sterilisation box; 1 x heater cover |
|
Optional accessories |
1 x Stainless steel tray frame; 3 x stainless steel tray; 1 x stainless steel tray pulling holder; 2 x stainless steel sterilisation spring holders |
Ordering information:
|
8417 |