ESSENTIAL gel documentation systems

home  -   contact  -   site map
 

ESSENTIAL gel documentation systems

The systems which fit your budget
 
Features:
  • Extreme ease of use
  • Ideal for multi-user environments
  • Sony scientific grade CCD camera
  • Patent pending UVI-PURE technology available
  • Comprehensive range of models for any application or budget
  • Ideal for multi-user environment
  • Good Laboratory Practice (GLP) file
  • Free software for image acquisition, annotation and quantification
  • Camera and optics: Sony scientific grade camera with electronically variable shutter speed; 0.5 Megapixels; super-high sensitivity; 8-bit performance (256 grey levels); 6 times optical zoom;
  • Choice of D55 or D77 steel and stainless steel darkroom epoxy painted for chemical resistance, black body imaging grade; smart control panel with UV security option; roll-out transilluminator; UV-PURE option; single (312nm.) or dual (312 and 365nm.) for preparative work;
ESSENTIAL D77 has scientific grade camera with manual or motorised zooms lens options, multi-position filter wheel, smart control panel with UV security option, roll-out transilluminator / UV-PURE option, UV security timer; 6 illumination options; optional Epi-Bright multi-wavelength epi-illumination source
ESSENTIAL D55 has scientific grade camera with manual or motorised zoom lens options, high resolution video monitor and 3-position filter slide, smart control panel with UV security option, roll-out transilluminator / UV-PURE option, UV security timer, optional Epi-Bright multi-wavelength epi-illumination source
  • Software: ESSENTIAL 1D software for image enhancement, annotation and illustration with 3 analysis modules: 1D nucleic acid; Colony counting; Distance calculation (RF, IEF). Highlight important features with text and symbols as the software helps you to annotate and illustrate your image. Your image can be enhanced with the extensive and readily available set of tools such as multiple colour channels, cropping and image additions. If you need to quantify or measure then just add a calibration marker for reference or measure the volumes to determine the quantity with the software’s simple 1-2-3- approach.
  • Applications: 1D nucleic acid; 1D protein gel; Microtitration plate or array; Multiplexing samples; Plant and bioluminescent samples; Petri dish imaging; Flash imaging
  • Options: Transilluminator UV surface 26 x 21 or 20 x 20 cm.; UV-PURE transilluminator or standard transilluminator; single or dual wavelength available; manual or motorised zoom lens; UV to white light or UV to blue conversion screen; advanced UVI-Band or UVI-BandMap software
Ordering information:
Cat. number
Description
1341 4402 1
ESSENTIAL D-55-20M
Includes: Software and acquisition board; Camera; Manual zoom; Ethidium filter; Darkroom D-55 with Transilluminator 8W, 312nm. filter 20 x 20 cm.
1341 4401 1
ESSENTIAL D-55-26M
Includes: Software andacquisition board; Camera; Manual zoom; Ethidium filter; Darkroom D-55 with Transilluminator 8W, 312nm. filter 21 x 26 cm.
1341 4502 1
ESSENTIAL D-55-20M-Auto
Includes: Software and acquisition board; Camera; Motorised zoom; Ethidium filter; Darkroom D-55 with Transilluminator 8W, 312nm. filter 20 x 20 cm.
1341 4501 1
ESSENTIAL D-55-26M-Auto
Includes: Software and acquisition board; Camera; Motorised zoom; Ethidium filter; Darkroom D-55 with Transilluminator 8W, 312nm. filter 21 x 26 cm.
1341 3402 1
ESSENTIAL D-77WL-20M
Includes: Software and acquisition board; Camera; Manual zoom; Ethidium filter; Darkroom D-77WL with Transilluminator 8W, 312nm. filter 20 x 20 cm.
1341 3401 1
ESSENTIAL D-77WL-26M
Includes: Software and acquisition board; Camera; Manual zoom; Ethidium filter; Darkroom D-77WL with Transilluminator 8W, 312nm. filter 21 x 26 cm.
1341 2402 1
ESSENTIAL D-77LS-20M
Includes: Software and acquisition board; Camera; Manual zoom; Ethidium filter; Darkroom D-77LS with Transilluminator 8W, 312nm. filter 20 x 20 cm.
1341 2401 1
ESSENTIAL D-77LS-26M
Includes: Software and acquisition board; Camera; Manual zoom; Ethidium filter; Darkroom D-77LS with Transilluminator 8W, 312nm. filter 21 x 26 cm.
1341 3502 1
ESSENTIAL D-77WL-20M-Auto
Includes: Software and acquisition board; Camera; Motorised zoom; Ethidium filter; Darkroom D-77WL with Transilluminator 8W, 312nm. filter 20 x 20 cm.
1341 3501 1
ESSENTIAL D-77WL-26M-Auto
Includes: Software and acquisition board; Camera; Motorised zoom; Ethidium filter; Darkroom D-77WL with Transilluminator 8W, 312nm. filter 21 x 26 cm.
1341 2502 1
ESSENTIAL D-77LS-20M-Auto
Includes: Software and acquisition board; Camera; Motorised zoom; Ethidium filter; Darkroom D-77LS with Transilluminator 8W, 312nm. filter 20 x 20 cm.
1341 2501 1
ESSENTIAL D-77LS-26M-Auto
Includes: Software and acquisition board; Camera; Motorised zoom; Ethidium filter; Darkroom D-77LS with Transilluminator 8W, 312nm. filter 21 x 26 cm.
Options:
1710 4123 1
F-520 M58 Syber Green interference filter
1440 1001 1
UVIband software
9120 2002 1
FC-26.WL UV/WL conversion screen
9120 2003 1
FC-26.BLUE UV/BLUE conversion screen
1710 5301 1
P-93E Mitsubishi thermal printer

 
Search
Search Site:
Make an Enquiry








Brochures
Progen Focus 2008 Download Adobe Acrobat Reader
Food, Feed and Environmental Analysis Equipment from Progen Scientific Progen Five Star Capital Equipment
To view the brochures you will need to have Acrobat Reader
 
Site Build and Hosting by Wizzy Design Ltd.  |   Design By Website Optimisation  |   Powered By Apex CMS ©
ESSENTIAL gel documentation systems © Progen Scientific Ltd. 2008. All Rights Reserved.