Milwaukee Sharp Handheld Waterproof Conductivity & TDS Meters
Milwaukee Sharp Handheld Waterproof Conductivity & TDS Testers
These simple and easy to use testers are designed for all applications. Their IP67 waterproof casing and replaceable probe make them suitable for heavy duty applications, such as waste water treatment and agriculture.
The modular design allows easy probe and battery replacement.
Four models are available and all have Automatic Temperature Compensation (ATC):
- C65: Conductivity tester low range: 0 to 1999 μS / cm
- C66: Conductivity tester high range: 0.00 to 10.00 mS / cm
- T75: TDS tester low range: 0 to 1999 ppm (mg./ L)
- T76: TDS tester high range: 0 to 9990 ppm (mg. / L)
Ordering information:
C65 and C66 are supplied complete with protective cap, 20ml. 1413 μS / cm sachet of calibration solution, hard carrying case, calibration screwdriver, batteries ad instructions.
T75 is supplied complete with protective cap, 20ml. 1382 ppm. sachet of calibration solution, hard carrying case, calibration screwdriver, batteries and instructions.
T76 is supplied complete with protective cap, 20ml. 6.44 ppt. sachet of calibration solution, hard carrying case, calibration screwdriver, batteries and instructions.
Specifications:
|
Model
|
C65 Waterproof EC
|
C66 Waterproof EC
|
T75 Waterproof TDS
|
T76 Waterproof TDS
|
|
Range:
|
0 to 1999 μS / cm
|
0.00 to 10.00 mS / cm |
0 to 1999 ppm (mg/L) |
0 to 9990 ppm (mg/L) |
|
Resolution:
|
1 μS / cm |
0.01 mS / cm |
1 ppm (mg/L) |
10 ppm (mg/L) |
|
Accuracy:
|
± 2% full scale |
± 2% full scale |
± 2% full scale |
± 2% full scale |
|
Typical EMC Deviation . |
± 2% full scale |
± 2% full scale |
± 2% full scale |
± 2% full scale |
|
Temperature compensation |
automatic from 5 to 50°C with β = 2%/°C |
automatic from 5 to 50°C with β = 2%/°C |
automatic from 5 to 50°C with β = 2%/°C |
automatic from 5 to 50°C with β = 2%/°C |
|
TDS Factor |
|
|
0.5 |
0.5 |
|
Calibration |
manual at 1 point via trimmer |
manual at 1 point via trimmer |
manual at 1 point via trimmer |
manual at 1 point via trimmer |
|
Probe |
MA73075 (replaceable) |
MA73076 (replaceable) |
MA73075 (replaceable) |
MA73076 (replaceable) |
|
Environment |
0 to 50°C, max. RH 100% |
0 to 50°C, max. RH 100% |
0 to 50°C, max. RH 100% |
0 to 50°C, max. RH 100% |
|
Battery type |
3 x 1.5V, alkaline |
3 x 1.5V, alkaline |
3 x 1.5V, alkaline |
3 x 1.5V, alkaline |
|
Battery life |
approx. 250 hours continuous use |
approx. 250 hours continuous use |
approx. 250 hours continuous use |
approx. 250 hours continuous use |
|
Dimensions |
165x30x30 mm. |
165x30x30 mm. |
165x30x30 mm. |
165x30x30 mm. |
|
Weight |
80 g. |
80 g. |
80 g. |
80 g. |
Accessories:
|
Cat. number
|
Description
|
|
MA73075 |
Replaceable Conductivity probe, low range |
|
MA73076 |
Replaceable Conductivity probe, high range |
|
M10030B |
12880 μS / cm calibration solution, 20ml. sachet (25 pieces) |
|
M10031B |
1413 μS / cm calibration solution, 20ml. sachet (25 pieces) |
|
M10032B |
1382 ppm (mg/L) calibration solution, 20ml. sachet (25 pieces) |
|
M10038B |
6.44 ppt(g/L) calibration solution, 20ml. sachet (25 pieces) |
|
M10080B |
800 ppm calibration solution, 20ml. sachet (25 pieces) |