Halo DB-20 UV / Visible Double Beam Spectrophotometer

The Halo DB-20 is a high performance double beam spectrophotometer suitable for many analytical applications where a higher level of accuracy is required.
Genuine Double Beam Optics
True double beam optics ensure concurrent measurement of the sample and reference for improved stability, accuracy and reproducibility. The light beam is split in two using a half mirror so that one beam passes through the sample whilst the other passes through the reference side. Both beams are then measured on individual detectors. The reference side beam also acts to stabilise photometric values in a similar manner to the ratio beam principle.
Spectral Features
Coma aberration elimination from the concave diffraction grating achieves a high resolution 1.5 nm. spectral bandpass and certifies compliance of the Halo DB-20 to the stringent European Pharmacopoeia standards.
Other specifications include an impressive wavelength accuracy of ± 0.3 nm., noise level 0.0003 Abs (500 nm.) and stray light ≤ 0.05% (220 nm. NaI, 340 nm. NaNO2)
Built-in and Diverse Range of Measurement Modes
Photometry Mode:Perform quantitative analyses in either absorbance or transmittance modes. Select from single wavelength, up to 6 individual wavelengths, nucleic acid / protein A260/A280 ratios and set up calibration curves with up to 20 standards for concentration measurements.
Time Scan:Perform kinetic measurements for time periods ranging from 1 minute to > 27 hours. Measurement intervals are factory preset and automatically selected when the scan time is set.
Wavelength Scan:Perform a full spectral scan from 190 to 1100 nm. at any of 8 incremental and preset selectable selectable scan speeds starting from a high resolution 10 nm. / minute up to a swift 3600 nm. / minute. Data is displayed as either numerical values or a graphical spectrum. Furthermore, perform downstream processing of data, such as peak / valley search or smoothing, directly on board or with the optional Halo UV Detective software.
Dual Lamp Advantage
By virtue of the halogen tungsten and deuterium lamps typically found in higher end, analytical spectrophotometers, the Halo DB-20 wavelength range is an impressive 190 to 1100 nm. Furthermore, the dual lamp system results in higher accuracy then corresponding xenon lamps. Lamp switching is automatic and selectable from a wavelength range of 325 nm. to 370 nm. and both lamps are long life.
User friendly operation and information rich LCD display
The extra large 190 mm. x 138 mm., backlit LCD screen with adjustable brightness control displays a large array of data also in graphical format. The seamless and chemical resistant keypad is designed for easy and quick selection of navigation and function features whilst protecting against any laboratory spills. Other unique features include the ‘GO TO WL’ short cut key to allow direct input of a new wavelength into an existing measurement.
Validation Functions
To ensure optimum instrument performance, a self-diagnostic function incorporating a number of parameters and wavelength calibration are automatically initiated upon start-up. Furthermore, the Halo DB-20 is equipped with a GLP / GMP feature for analyses requiring validation and auditing. Parameters such as wavelength accuracy, wavelength reproducibility, bandpass, baseline flatness, baseline stability and noise level can be all validated and the audit report printed.
Stand alone or PC Operation
The Halo DB-20 is fully equipped and capable of executing all functions in stand alone mode. Simply connect a standard laser printer for direct printouts of data and graphs. For more advanced analyses and reporting, the single slide of a switch places the Halo DB-20 under the direct control of the optional UV Detective™ software installed on a computer with Windows® XP Pro operating system (see separate specifications).
On-Board Data Storage
Up to 80 operating programmes and up to 10 sets of measurement data can be stored in the flash memory of the Halo DB-20. Programmes can easily be recalled, edited and deleted. Furthermore, when in stand alone mode, data (in text format) can be downloaded directly to an external memory stick via the USB port and transferred for further processing to any computer loaded with commercial spreadsheets (such as Microsoft® Eccel).
Halo UV Detective™ Software
Halo UV Detective™ is powerful, user friendly software specifically designed for the control (and data processing) of selected Halo spectrophotometers from computers installed with the Windows® XP Pro operating system.
The versatile UV Detective™ can control all spectrophotometer operations such as photometry, wavelength scans, time scans and more. Further functions include storage of methods programme, saving of numerical and graphical data, downstream data processing, data transfer to commercial spreadsheets such as Microsoft™ Excel and report generation.
Specifications:
|
Compatible Spectrophotometers
|
Halo RB-10 (optional), Halo DB-20 (optional), Halo DB-30 (standard)
|
|
Control Functions
|
Wavelength setting, auto-zero, auto calibration, optical path calibration, accessories such as 6-cuvette positioner and sipper
|
|
Measurement Conditions
|
Start-up, setting, output and storage of measurement parameters
|
|
Measurement Function
|
Wavelength scan, time scan, quantitative analysis, multi-spectrum measurement, kinetic analysis, concentration measurement and nucleic acid / protein measurements
|
|
Data Output
|
Display of spectra, data and scans (time and spectrum)
|
|
Quantitative Methods
|
Multi-wavelength, input of constant, standard curve calibration (linear, quadratic, cubic and segment)
|
|
Data Processing
|
Integral, derivative, flatness, calculation (spectrum and constant) and kinetic
|
DB-20 Accessories
Rectangular long-path cuvette holder: Designed for low concentration or low absorbance samples
- Accomodates 2 x long-path cuvettes
- Accepts cuvettes with 6 optical path lengths of: 10, 20, 30, 40, 50 & 100 mm.
Cylindrical long-path cuvette holder: Designed for low concentration or low absorbance samples using a cylindrical cuvette.
- Accomodates 2 x long-path cylindrical cuvettes (sample and reference sides)
Thermostatic cuvette holder: Designed for applications requiring incubation and / or maintenance of a sample at a constant temperature.
- External water circulation maintains temperature stability
- Operating temperature range: ambient to +40°C
- Temperature stability: ± 0.3°C
- Complete with tubing for quick connection to water source (such as circulating water bath)
5-Cuvette holder / changer: Designed for mounting up to 5 standard 10 mm. cuvettes on the sample beam side.
- Total capacity: 5 cuvettes on sample beam side + 1 cuvette on reference beam side
- Turret design cuvette holder for efficient changeover
- Manual change of cuvettes by turning front mounted knob
- No temperature control
6-Cuvette holder / changer with electronic temperature control: Designed for mounting up to 6 standard 10 mm. cuvettes on the sample beam side with temperature control and stirring.
- Total capacity: 6 cuvettes on sample beam side + 1 cuvette on reference beam side
- Electronic changeover - change cuvettes automatically at defined time intervals
- Electronic thermostat – set temperature between +20°C to +40°C
- Includes magnetic stirrer (and fleas)
- Requires water circulated cooling (tubing included)
Micro-cuvette holder: Designed for measuring micro-volumes with 50μl. micro-cuvette.
- Wavelength range: 220 to 950 nm.
- Noise level: - 0.005 Abs (with 50μl. volumes)
Micro-cuvettes: Suitable for use in the micro-cuvette holder.
- Made from quartz
- Available size: 50μl.
Auto Sample sipper (without temperature control): Designed for the rapid measurement of multiple or large amounts of sample without the requirement for manual washing or changing of cuvettes. Sample is sipped from an external tube directly into the sipper’s integrated cuvette and automatically measured. The sample can also be recovered post-measurement.
- Minimum sample volume: 0.7 ml.
- Wavelength range: 190 nm. – 900 nm.
- Carryover: ≤ 1%
- Sipper cuvette capacity: approx. 50μl.
- Optical path length: 10 mm.
Auto Sample sipper (with temperature control): The same features as the Auto sipper with the added convenience of electronic temperature control to maintain the flow cuvette at a constant temperature.
- Temperature control range: +20° to +40°C
- Requires water circulated cooling (tubing included)
Micro Flow Cuvette Holder
Designed for the continuous measurement of trace samples. The sample can be injected into the flow cuvette with a syringe or other injection device.
- Flow cuvette capacity: 70 μl.
- Pressure tolerance: Max. 0.1 Mpa
- Optical path length: 10 nm.
- Teflon tubing provided
Glass Sample Holder
Designed for measuting the transmittance / absorbance of glass samples or filters.
- Glass sample thickness: 0.5 mm. to 5 mm.
- Glass sample dimensions: Min. 12 x 25 mm. to Max. 55 x 100 mm.
Film Sample Holder
Designed for measuting the transmittance / absorbance of thin film-like samples.
- Film sample dimensions: 25 mm. (W) x 30 – 50 mm. (H)
- Beam aperture: 10 mm. (W) x 20 mm. (H)
Specifications:
|
Optics
|
Concave diffraction grating / Double beam principle
|
|
Wavelength range
|
190 nm. – 1100 nm.
|
|
Spectral bandwidth
|
1.5 nm.
|
|
Stray light
|
≤ 0.05% (220 nm. NaI, 340 nm. Na NO2)
|
|
Wavelength accuracy
|
± 0.3 nm.
|
|
Photometric range
|
Absorbance: -3 to +3
%T: 0% to 300% T
|
|
Wavelength scan speed
|
10, 100, 200, 400, 800, 1200, 2400, 3600 nm. / minute
|
|
Baseline stability
|
0.0003 Abs / hr. (500 nm. after 2 hours)
|
|
Noise level
|
0.0003 Abs (500 nm.)
|
|
Light source
|
Tungsten-Halogen and Deuterium lamps
|
|
Light source switching
|
Automatic switching selectable from 325 nm. to 370 nm..
|
|
Detector
|
Silicone Photodiode
|
|
Display
|
Back-lit LCD 190W x 138H mm.
|
|
Dimensions
|
505W x 705D x 225H mm.
|
|
Net weight
|
29 kg.
|
|
Gross weight
|
35 kg.
|
|
Power requirements
|
110 – 220V selectable, 50/60 Hz
|
Ordering information:
|
Catalogue number
|
Description
|
|
DB-20-220
|
Dynamica Halo DB-20 UV/Visible Double Beam Spectrophotometer 110 – 220V selectable, 50/60 Hz Includes: #46-03-0007 Quartz cuvette (pack of 2) and #T151383 USB Data Storage Unit |
|
DB-20-RLPH
|
Rectangular long-path cuvette holder
|
|
DB-20-CLPH
|
Cylindrical long-path cuvette holder
|
|
DB-20-TCH
|
Thermostatic cuvette holder with tubing
|
|
DB-20-FCC
|
Manual 5-cuvette holder / changer
|
|
DB-20-SCCT
|
Auto 6-cuvette holder / changer with temperature control and stirrer
|
|
DB-20-SCC
|
Auto 6-cuvette holder / changer without temperature control and stirrer
|
|
DB-20-MCH
|
Micro-cuvette holder
|
|
DB-20-MC-50
|
Micro-cuvettes – quartz 50 μl / 10 mm. optical path length
|
|
DB-20-SST
|
Auto sample sipper with temperature control
|
|
DB-20-SS
|
Sample sipper without temperature control
|
|
DB-20-MFH
|
Micro flow cuvette holder
|
|
DB-20-GSH
|
Glass sample holder
|
|
DB-20-FSH
|
Film sample holder
|
|
UVDS-08-01
|
UV Detective™ software (see separate specifications)
|