Fire-Reader gel documentation systems

home  -   contact  -   site map
 

Fire-Reader gel documentation systems

The Fire-Reader is a 1.4 megapixels gel documentation system ideal for documentation, publication and quantification. The very high resolution provides more quantification data as the image contains more details. The Fire-Reader has 16-bit performance (65,536 grey levels) as compared with 12-bit competitor systems. The dynamic range (4.8 OD) describes the ratio between the maximum and minimum measurable light intensities. Light measurements are translated into digital values with precision measured by the bit depth. The Fire-Reader extended dynamic range provides for more quantification data.

 

Features:

 

  • Massive 16-bit performance (65,536 grey levels) – 1.4 Megapixels
  • 6 wavelength illumination options. Biofluorescence and multiplexing ready. Multi-position filter slide. Custom filters available
  • Patent pending UVI-PURE technology available for the imaging of dyes such as SYBR Green and Sypro Ruby achieving enhanced image quality and 25% better signal in comparison with standard systems
  • Extreme sensitivity for the faintest fluorescence sample
  • Suitable for both routine documentation and critical quantitative applications
  • Versatile and upgradeable
  • Autofocus and focusing gauge – motorised or manual scientific zoom lens
  • ‘One touch’ fully automated image acquisition programme
  • Wide variety of darkrooms and options to tailor your own system and fit your budget
  • Scientific Sony chip CCD camera – USB connection
  • Superb quality camera filter optimized for ethidium bromide
  • Camera and optics: Sony scientific grade camera with electronically variable shutter speed, Grade 0 chip quality and zero defect; 1.4 Megapixels; extreme sensitivity for fluorescence; 16-bit performance (65,536 grey levels); 6 times optical zoom with choice of manual (focusing gauge) or motorised configurations (autofocus); dynamic range 4.8 OD; progressive scan – low dark current; USB super-fast connection
  • Choice of D55 or D77 steel and stainless steel darkroom epoxy painted for chemical resistance, black body imaging grade; smart control panel with UV security option; roll-out transilluminator; UV-PURE option; single (312nm.) or dual (312 and 365nm.) for preparative work;
  • Fire-Reader D77 has scientific grade camera with manual or motorised zoom lens options; multi-position filter wheel; smart control panel; 8-Watt built-in, roll-out transilluminator (UV-PURE option); UV timer and security timer; 12 wavelengths illumination options; Bio-fluorescence and multiplexing ready; optional Epi-Bright multi-wavelength epi-illumination source can be used for protein detection and comprises of LED lamps which can be switched between green, blue and red illumination depending on the dye being used

 

Fire-Reader D55 has scientific grade camera with manual or motorised zoom lens options; high resolution video monitor; 3-position filter slide; smart control pane;; 8-Watt built-in, roll-out transilluminator(UV-PURE option); UV timer and security switch; white light epi-illumination

 

  • Software: Fire-Reader 1D software ‘one touch’ fully automated image acquisition programme for image enhancement, annotation and illustration with 3 analysis modules: 1D Molecular Weight (MW, volume, intensity,…..); Colony counting; Distance calculation (RF, IEF,……).

 

Your gel on live! The live preview mode ensures quick and easy sample positioning and fine focus. Auto-focus, auto-exposure and video mode included!
Getting the word out: Highlight important features with text and symbols. The software helps you to annotate and illustrate your image
Create vibrant images: Enhance your image with the extensive and readily available set of tools such as multiple colour channels, cropping and image additions

Need to quantify or measure? Just add a calibration marker for reference or measure the volumes to determine the quantity with the simple 1-2-3 approach

 

  • Applications: 1D nucleic acid; 1D protein gel; Microtitration plate or array; Multiplexing samples; Plant and bioluminescent samples; Petri dish imaging; Flash imaging
  • Options: Transilluminator UV surface 26 x 21 or 20 x 20 cm.; UV-PURE transilluminator or standard transilluminator; single or dual wavelength available; manual or motorised zoom lens; UV to white light or UV to blue conversion screen; advanced UVI-Band or UVI-BandMap software enable the user to convert images into useful, publishable data easily. In designing UVIband packages, a realistic, professional approach has been taken and only those features included which are of genuine benefit to the user.

 

As a result, all UVIband packages are:
Powerful:UVIband analysis packages include many special features such as two alternative methods for correction of local and global gel distortions e.g. a ‘smile’ or ‘frown’ across the gel.
Reliable: Fully automatic background subtraction for band quantification provides consistency and reliability
User friendly: Every aspect of UVIband is designed with ease of use in mind. This includes the very first step of searching for an image to analyse which is facilitated by the ability to choose the file from a gallery of ‘thumbnail’ images

Flexible: Attractive as it may sound, so-called ‘One Step’ analysis places excessive reliance on automation, resulting , in the best case, in inaccurate data, and in the worst, in totally irrevevant data from your image!

 

Ordering information:

Cat. number
Description
1041 4172 1
FIRE-READER XS-D 55-20M
Includes: 1D Software; Camera; Manual zoom; Ethidium filter; Darkroom D-55 with Transilluminator 8W, 312nm. filter 20 x 20 cm.
1041 4171 1
FIRE-READER XS-D 55-26M
Includes: 1D Software; Camera; Manual zoom; Ethidium filter; Darkroom D-55 with Transilluminator 8W, 312nm. filter 21 x 26 cm. 
1041 4173 1
FIRE-READER XS-D 55-26MX
Includes: 1D Software; Camera; Manual zoom; Ethidium filter; Darkroom D-55 with 26.MX Transilluminator 8W UVI PURE, 312nm. filter 21 x 26 cm. 
1041 4272 1
FIRE-READER XS-D 55-20M Auto
Includes: 1D Software; Camera; Motorised zoom; Ethidium filter; Darkroom D-55 with Transilluminator 8W, 312nm. filter 20 x 20 cm.
1041 4271 1
FIRE-READER XS-D 55-26M Auto
Includes: 1D Software; Camera; Motorised zoom; Ethidium filter; Darkroom D-55 with Transilluminator 8W, 312nm. filter 21 x 26 cm.
1041 4273 1
FIRE-READER XS-D 55-26MX Auto
Includes: 1D Software; Camera; Motorised zoom; Ethidium filter; Darkroom D-55 with 26.MX Transilluminator 8W UVIpure, 312nm. filter 21 x 26 cm.
1041 6172 1
FIRE-READER XS-D 77WL-20M
Includes: 1D Software; Camera; Manual zoom; Ethidium filter; Darkroom D-77WL with Transilluminator 8W, 312nm. filter 20 x 20 cm.
1041 6171 1
FIRE-READER XS-D 77WL-26M
Includes: 1D Software; Camera; Manual zoom; Ethidium filter; Darkroom D-77WL with Transilluminator 8W, 312nm. filter 20 x 20 cm.
1041 6173 1
FIRE-READER XS-D 77WL-26MX
Includes: 1D Software; Camera; Manual zoom; Ethidium filter; Darkroom D-77WL with 26.MX Transilluminator 8W UVIpure, 312nm. filter 21 x 26 cm.
1041 6272 1
FIRE-READER XS-D 77WL-20M Auto
Includes: 1D Software; Camera; Motorised zoom; Ethidium filter; Darkroom D-77WL with Transilluminator 8W, 312nm. filter 20 x 20 cm.
1041 6271 1
FIRE-READER XS-D 77WL-26M Auto
Includes: 1D Software; Camera; Motorised zoom; Ethidium filter; Darkroom D-77WL with Transilluminator 8W, 312nm. filter 21 x 26 cm.
1041 6273 1
FIRE-READER XS-D 77WL-26MX Auto
Includes: 1D Software; Camera; Motorised zoom; Ethidium filter; Darkroom D-77WL with 26.MX Transilluminator 8W UVIpure, 312nm. filter 21 x 26 cm.
1041 7172 1
FIRE-READER XS-D 77LS-20M
Includes: 1D Software; Camera; Manual zoom; Ethidium filter; Darkroom D-77LS with Transilluminator 8W, 312nm. filter 20 x 20 cm.
1041 7171 1
FIRE-READER XS-D 77LS-26M
Includes: 1D Software; Camera; Manual zoom; Ethidium filter; Darkroom D-77LS with Transilluminator 8W, 312nm. filter 21 x 26 cm.
1041 7173 1
FIRE-READER XS-D 77LS-26MX
Includes: 1D Software; Camera; Manual zoom; Ethidium filter; Darkroom D-77LS with Transilluminator 8W UVIpure, 312nm. filter 21 x 26 cm.
1041 7272 1
FIRE-READER XS-D 77LS-20M Auto
Includes: 1D Software; Camera; Motorised zoom; Ethidium filter; Darkroom D-77LS with Transilluminator 8W, 312nm. filter 20 x 20 cm.
1041 7271 1
FIRE-READER XS-D 77LS-26M Auto
Includes: 1D Software; Camera; Motorised zoom; Ethidium filter; Darkroom D-77LS with Transilluminator 8W, 312nm. filter 21 x 26 cm.
1041 7273 1
FIRE-READER XS-D 77LS-26MX Auto
Includes: 1D Software; Camera; Motorised zoom; Ethidium filter; Darkroom D-77LS with Transilluminator 8W UVIpure, 312nm. filter 21 x 26 cm.
Options:
9141 1120 1
FP-77 Build-in safety screen D-77
3949 9009 1
EPI-BRIGHT 3 LED illumination system
1710 4160 1
F-565 M58 Interference Filter Qdot
1710 4161 1
F-655 M58 Interference Filter Qdot
1710 4162 1
F-710 M58 Interference Filter Qdot
1710 4123 1
F-520 M58 Syber Green interference filter
1710 4156 1
F-R66 M58 Filter for red excitation
1710 4158 1
F-O58 M58 Filter for green excitation
1710 4155 1
F-CM5 M58 Filter for green excitation 2
1440 1001 1
UVIband software
9120 2002 1
FC-26.WL UV/WL conversion screen
9120 2003 1
FC-26.BLUE UV/BLUE conversion screen
1710 5302 1
P-93DW Digital Mitsubishi printer
 

 


 
Search
Search Site:
Make an Enquiry

Brochures
Progen Focus 2008 Part 1 Download Adobe Acrobat Reader
Progen Focus 2009 Part 2 Food, Feed and Environmental Analysis Equipment from Progen Scientific
To view the brochures you will need to have Acrobat Reader
 
Site Build and Hosting by Wizzy Design Ltd.  |   Design By Website Optimisation  |   Powered By Apex CMS ©