Orto Alresa Consul 21R refrigerated benchtop centrifuge, 4 x 400ml.
Features:
- Induction motor, maintenance free
- Stainless steel chamber
- Buckets with lids
- Max. speed: 13,300 rpm / 18,985 x g. (with 30 x 1.5/2.0ml. angle rotor)
4,000 rpm / 3,274 x g. (with 4 x 200ml. swing-out rotor)
- Temperature range from -20°C to +40°C
- Pre-cooling programme with temperature selectable
- Temperature probe inside chamber
- Microprocessor controlled
- Motorised lid latch
- Controlled by RPM or RCF
- Minimum acceleration time
- Lights for short cycle, open lid, start and stop
- Display of current parameter in values or graphics
- Radius selectable
- TFT full colour screen and sealed keypad for selection of speed and time:
- speed in steps of 100 rpm, RCF in steps of 10 x g.
- time selection from 1 to 99 minutes and hold position
- temperature regulation from -20°C to 40°C (or °F selectable)
- screen shows the values or graphics of set and update
- screen messages indicate current device state
- Braking ramps from 5 to 180 seconds
- Countdown starts after selected speed is reached, or counts up from 0
- Short cycle key allows centrifuge to reach maximum speed while it is pressed
- Up to 16 programmable memories can be stored
- Rotors and adaptors list on memory
- Aluminium rotors, autoclavable
- Noise level: < 60 dB
- Automatic rotor recognition shows on screen: max. RCF, max. speed, max. capacity and overspeed control
- Continuous verification about centrifuge state and accessories
- Rubber protection gasket around lip of centrifuge chamber
- Imbalance detection and switch-off
- Double manual emergency lid opening mechanism
- Lid lock so rotor will not run if lid open and lid will not open if rotor running
- Lid opening can be programmed automatically at end of run or by pressing lid open button
- Lid dropping protection
- Bucket lids available
- Dimensions: 670W x 770D x 390H mm.
- Weight: 72 kg.
Ordering information:
|
Cat. number |
Description |
|
CE 114 |
Consul 21R refrigerated benchtop centrifuge, 220-240V, 50-60 Hz |
|
Rotors and adaptors |
|
|
RT 197 |
Angle fixed rotor 45º for 8 x 50ml. tubes (encoder) max. speed 5,000 rpm / 4,165 x g., radius 149 mm.; min. temp. -4°C |
|
RE 375 |
8 adaptors for 8x 50ml. Falcon tubes |
|
RE 370 |
8 adaptors for 8 tubes of 30 ml. |
|
RE 369 |
8 adaptors for 8 tubes of 10 ml. vacuum , 15 ml. vacuum , 15 ml. or 15ml. Falcon |
|
RE 366 |
8 adaptors for 24 tubes of 5 ml. or 10 ml. |
|
RE 373 |
8 adaptors for 8 tubes of 5 ml. vacuum or 7/10 ml. vacuum |
|
RE 367 |
8 adaptors for 24 tubes of Hemolisis of 10 x 100 mm. |
|
|
|
|
RT 198 |
Angle fixed rotor 45º for 4 x 100ml. tubes (encoder) max. speed 5,200 rpm / 4,172 x g., radius 138 mm.; min. temp. -4°C |
|
RE 380 |
4 adaptors for 4 tubes of 80 ml. Herolab |
|
RE 338 |
4 adaptors for 4 tubes of 80 ml. |
|
RE 381 |
4 adaptors for 4 tubes of 50 ml. Herolab |
|
RE 335 |
4 adaptors for 4 tubes of 50 ml. in 100 ml. |
|
RE 341 |
4 adaptors for 4 x 50ml. Falcon tubes. in 100 ml. |
|
RE 382 |
4 adaptors for 4 tubes of 30 ml. Herolab |
|
RE 332 |
4 adaptors for 4 tubes of 30 ml. |
|
RE 316 |
4 adaptors for 16 tubes of 10 ml. vacuum , 10 ml. Herolab or 15 ml. |
|
RE 339 |
4 adaptors for 4 x 15ml. Falcon tubes |
|
RE 320 |
4 adaptors for 20 tubes of 5 ml. vacuum , 7/10 ml. vacuum , 5 ml. or 10 ml. |
|
RE 408 |
4 adaptors for 20 x 1.5/2.0ml. microtubes |
|
RE 326 |
4 adaptors for 36 tubes of Hemolisis of 10 x 100 mm. in 100ml |
|
|
|
|
RT 199 |
Angle fixed rotor 30º for 4 x 250ml. tubes (encoder) max. speed 4,700 rpm / 3,779 x g., radius 153 mm.; min. temp. -4°C |
|
RE 327 |
4 adaptors for 4 tubes of 100 ml. |
|
RE 422 |
4 adaptors for 4 tubes of 80 ml. in 250 ml. |
|
RE 334 |
4 adaptors for 4 tubes of 50 ml. |
|
RE 340 |
4 adaptors for 4 x 50ml. Falcon tubes |
|
RE 312 |
4 adaptors for 12 tubes of 30 ml. |
|
RE 321 |
4 adaptors for 20 x 15ml. Falcon tubes |
|
RE 376 |
4 adaptors for 28 tubes of 10 ml. vacuum , 15 ml. vacuum or 15 ml. |
|
RE 343 |
4 adaptors for 40 tubes of 5 ml. or 10 ml. |
|
RE 324 |
4 adaptors for 28 tubes of 5 ml. vacuum or 7/10 ml. vacuum |
|
RE 346 |
4 adaptors for 52 tubes of Hemolisis of 10 x 100 mm. |
|
|
|
|
RT 203 |
Swing out rotor for 4 x 200ml. tubes (encoder) max. speed 4,000 rpm / 3,274 x g., radius 183 mm.; min. temp. -2°C |
|
RE 327 |
4 adaptors for 4 tubes of 100 ml. |
|
RE 422 |
4 adaptors for 4 tubes of 80 ml. in 250 ml. |
|
RE 334 |
4 adaptors for 4 tubes of 50 ml. |
|
RE 340 |
4 adaptors for 4 x 50ml. Falcon tubes |
|
RE 312 |
4 adaptors for 12 tubes of 30 ml. |
|
RE 321 |
4 adaptors for 20 x 15ml. Falcon tubes |
|
RE 323 |
4 adaptors for 28 tubes of 10 ml. vacuum or 15 ml. |
|
RE 343 |
4 adaptors for 40 tubes of 5 ml. or 10 ml. |
|
RE 324 |
4 adaptors for 28 tubes of 5 ml. vacuum or 7/10 ml. vacuum |
|
RE 346 |
4 adaptors for 52 tubes of Hemolisis of 10 x 100 mm. |
|
|
|
|
RT 205 |
Swing out rotor for 4 x 400ml. tubes (encoder) max. speed 3,700 rpm / 2,755 x g., radius 180 mm.; min. temp. -4°C |
|
RE 423 |
4 adaptors for 4 tubes of 350 ml. in 400 ml. |
|
RE 430 |
4 adaptors for 4 tubes 200 ml. in 400 ml. |
|
RE 412 |
4 adaptors for 4 tubes of 100 ml. in 400 ml. |
|
RE 421 |
4 adaptors for 4 tubes of 80 ml. in 400 ml. |
|
RE 413 |
4 adaptors for 12 x 50ml. Falcon tubes in 400 ml. |
|
RE 414 |
4 adaptors for 8 tubes of 50 ml. in 400ml. |
|
RE 415 |
4 adapors for 20 tubes of 30 ml. in 400 ml. |
|
RE 416 |
4 adaptors for 28 x 15ml. Falcon tubes in 400 ml. |
|
RE 417 |
4 adaptors for 48 tubes of 10 ml. vacuum or 15 ml. in 400 ml. |
|
RE 418 |
4 adaptors for 72 tubes of 5 ml. or 10 ml. in 400 ml. |
|
RE 419 |
4 adaptors for 48 tubes of 5 ml. vacuum or 7/10 ml. vacuum in 400 ml. |
|
RE 431 |
4 adaptors for 48 x 1.5/2.0ml. microtubes in 400 ml. |
|
RE 420 |
4 adaptors for 76 tubes of Hemolisis of 10 x 100 mm. in 400 ml. |
|
RE 405 |
4 lids for buckets of 400 ml. |
|
|
|
|
RT 206 |
Angle fixed rotor 45º for 30 x 1.5/2.0ml. microtubes (encoder) max. speed 13,300 rpm /18,985 x g., radius 96 mm.; min. temp. -4°C |
|
RE 428 |
30 adaptors for 30 x 0,5/0,6 ml. tubes |
|
RE 427 |
30 adaptors for 30 x 0,2/0,4 ml. tubes |