Genlab Hot Air Sterilisers
Features:
- Temperature range: 40°C to 250°C
- Temperature fluctuation: ± 0.75°C
- Exterior is sheet steel with an easy clean powder coated paint
- Interior chamber is hospital grade stainless steel
- Chamber fitted with fixed shelf runners and removable chrome plated wire grid shelves
- Fan circulation
- Heating is by Incoloy sheathed elements positioned around the fan
- Basic control system (standard on 200 litre capacity and below) comprises of a direct reading thermostat and overheat thermostat both with calibrated scales and tamper-proof locks. They also include main switch with indicator and heat and overheat indicators. Timing is via a simple 120 minute mechanical run back timer
- The digital control system (standard on 250 litre capacity and above and optional for 200 litre capacity and below) comprises a PID microprocessor digital controller with dual display of set and actual temperatures and a separate digital timer that is programmed for automatic run back when set temperature is reached (can be run without setting a time)
- As an option the units can be fitted with an audible alarm that signals when the process is complete
- All units 500 litre capacity and above have the door lock as standard (optional for 250 litre capacity and below)
Specifications:
|
Genlab cat. number |
Capacity (litres) |
Internal dimensions HxWxD cm. |
External dimensions HxWxD cm. |
No. of shelves |
No. of shelf positions |
Weight kg. |
|
HAS/50/SS |
50 |
45 x 32 x 35 |
56 x 68 x 50 |
2 |
3 |
31 |
|
HAS/75/SS |
75 |
45 x 49 x 35 |
56 x 85 x 50 |
2 |
3 |
39 |
|
HAS/100/SS |
100 |
45 x 49 x 46 |
56 x 85 x 61 |
3 |
4 |
48 |
|
HAS/125/SS |
125 |
55 x 49 x 46 |
66 x 85 x 61 |
3 |
5 |
57 |
|
HAS/150/SS |
150 |
55 x 49 x 54 |
66 x 85 x 69 |
3 |
5 |
66 |
|
HAS/200/SS |
200 |
75 x 49 x 54 |
86 x 85 x 69 |
4 |
7 |
85 |
|
HAS/250/SS/DIG |
250 |
91 x 51 x 52 |
127 x 69 x 69 |
5 |
7 |
95 |
|
HAS/350/SS/DIG |
350 |
91 x 61 x 62 |
127 x 79 x 79 |
5 |
7 |
110 |
|
HAS/425/SS/DIG |
425 |
91 x 61 x 77 |
127 x 79 x 94 |
5 |
7 |
140 |
|
HAS/500/SS/DIG |
500 |
114 x 61 x 77 |
150 x 79 x 94 |
5 |
9 |
155 |
|
HAS/650/SS/DIG |
650 |
114 x 77 x 77 |
150 x 142 x 95 |
5 |
9 |
170 |
|
HAS/750/SS/DIG |
750 |
128 x 77 x 77 |
164 x 142 x 95 |
5 |
10 |
190 |
|
HAS/850/SS/DIG |
850 |
142 x 77 x 77 |
178 x 142 x 95 |
5 |
11 |
210 |
|
HAS/1000/SS/DIG |
1000 |
142 x 77 x 92 |
178 x 142 x 110 |
5 |
11 |
230 |
All units have stainless steel interior and fan circulation as standard. For controller options on units 200 litre capacity and below simply add the option code to the original cat. number e.g. HAS/75/SS with digital system and audible alarm is HAS/75/SS/DIG/AWA
Option codes :
Digital control system: / DIG; Audible alarm: / AWA; Door lock: / DL