Novex RZ Series Stereo Zoom Microscopes
The Novex RZ Series stereo zoom microscopes for industrial and medical research applications are of exceptional quality.
Binocular and Trinocular Zoom Heads
The Novex RZ Series stereo zoom microscopes are available in both binocular and trinocular versions, 45º inclined viewing head 360º rotatable. The eyepieces have an interpupillary distance adjustment from 52 to 80 mm. and a dioptic adjustment.
Optics
The Novex RZ is equipped with a 1:7 ratio zoom objective. In combination with the standard wide field eyepieces, WF 10/20, magnifications of 6.5 to 45 times can be reached at a working distance of 95 mm. Different magnifications and working distances can be achieved with supplementary lenses and optional WF 15x/16, WF 20x/13 and WF 25x/12 eyepieces.
|
Eyepiece |
WF 10x (standard) |
WF 15x (optional) |
WF 20x (optional) |
|
Supplementary W.D. Lens |
Magnification F.O.V. mm. |
Magnification F.O.V. mm. |
Magnification F.O.V. mm. |
|
65.753 0.4x 225 mm. |
2.6 – 18x 82 - 12 |
3.9 – 27x 65 – 9.8 |
5.2 – 36x 52 – 8.0 |
|
65.754 0.5x 160 mm. |
3.2 – 22x 64 – 9.0 |
4.9 – 33.7 52 – 7.3 |
6.52 – 45x 41 – 6.0 |
|
65.755 0.75x 110 mm. |
4.8 – 33x 40 – 5.7 |
7.3 – 50.5x 32 – 4.7 |
9.8 – 67x 26 – 3.7 |
|
|
|
|
|
|
Standard 95 mm. |
6.5 – 45x 31 – 4.4 |
9.7 – 67.5x 25 – 3.6 |
13.0 – 90x 20 – 2.9 |
|
|
|
|
|
|
65.757 1.5x 40 mm. |
9.7 – 67x 20 – 2.9 |
14.6 – 101x 16 – 2.3 |
19.5 – 135x 13 – 1.9 |
|
65.758 2.0x 25 mm. |
13 – 90x 15 – 2.2 |
19.5 – 135x 12 – 1.7 |
26.0 – 180x 10 – 1.4 |
Remark: The printed values for the fields of view are typical
Parfocal
These microscopes are 100% parfocal, which means that the image remains in focus throughout the entire zoom range. The benefit of good quality parfocality is that the microscope does not require to be refocused when the magnification is changed.
The trinocular head is equipped with a vertical phototube with C-mount adaptor to connect a digital camera. When the phototube is not in use the image remains visible in one eyepiece. Adaptors for SLR cameras can be supplied on request.
Stands
PL Stand
This stand has an aluminium base with a chrome-plated column of 260 mm. x 30 mm. diameter. This particular stand does not have a built-in illuminator. PL stands are supplied with one black-white plastic stage plate and two object clamps.
SF stand
This stand is identical to the PL stand but has a built-in adjustable incident halogen illuminator, including daylight filter. The transmitted illumination is a fluorescence daylight type, 5 Watt, 6400ºK. By using one or two transparent stage plates you can vary the intensity of the transmitted illumination. SF-stands are supplied with two transparent stage plates, one black-white stage plate and two object clamps.
A large heavy stand for observation of larger objects up to 300 mm. in height. A 500 mm. x 38 mm. diameter vertical column is mounted on the heavy base, which is 255 x 255 mm. The horizontal arm can be positioned in all directions. The maximum distance from the vertical column to the optical axis is 660 mm. Weight is 18 kg. With the viewing head holder 65.720, the stereo zoom heads 65.700 or 65.710 can be mounted on to the horizontal arm.
LT Universal Stand
Identical to the LV Universal stand but equipped with a bench clamp to allow the microscope to be fixed to a bench with a maximum thickness of 65 mm.
Stereo Head Holder
With this holder a stereo zoom head (65.700 or 65.710) can be mounted on to universal stands (65.725 or 65.727).
Illumination
Good illumination of an object is crucial for stereo microscopy. When the correct illumination is chosen the details of the observed object will be more distinct. Comfort and desired light intensity are the factors that determine the choice.
EuroLed 56 and EuroLed 40 – 4300K
The ring light illuminators with respectively 56 or 40 white LED’s can both be adjusted between 10% and 100%. The colour temperature is a maximum 4300ºK. The LE.1970 and LE.1971 produce a clear and intense white light suitable for lengthy quality control applications.
Fluorescent Ring Illuminator
10 Watt fluorescent ring illuminator for incident illumination with ‘long-life’ lamp (> 5000 hours). For 230 Volts operation.
Fluorescent Ring Illuminator – 5200K
Fluorescent 40 kHz ring light for incident illumination. The colour temperature is a maximum 5200ºK. For 230 Volts operation. The 40 kHz frequency provides the user with a comfortable light which is excellent for lengthy microscopy sessions.
Cold-light Illuminators
Cold-light illuminators with a maximum colour temperature of 3100ºK are commonly used types of illumination. They are crucial when a high light intensity is required. For 230Volts operation only.
The 20 Watt cold-light source with light guide LE.5209 is compact and economical. The light intensity is factory pre-set and fixed. Supplied with a ‘flex & stay’ light guide, 40 cm. long, 6 mm. diameter.
The multi-functional 100 Watt cold-light source LE.5210 is a commonly used cold-light illuminator with a 100 Watt halogen lamp. The light intensity is fully adjustable. Supplied without light guide.
The multi-functional 150 Watt cold-light source LE.5211 is a new Euromex design cold-light illuminator with a 150 Watt halogen lamp. The light intensity is fully adjustable. Supplied without light guide.
Depending on the application, the cold-light sources LE.5210 and LE.5211 can be used with ‘flex & stay’ guides, fully flexible guides or fibre optic ring lights.
Positioning Tables
Positioning tables allow easy and precise positioning of objects when using high magnifications - e.g. in the electronic and mechanical industry – the X-Y table (AE.1950) with ball bearings is available. The size of this table is 395 x 395 x 30 mm.
The round positioning table AE.1960, 200 mm. diameter, is ideal to move objects freely around a central point smoothly and precisely.
Ordering information:
|
Model |
Description |
Remarks |
|
65.500 |
Binocular RZB microscope |
With PL stand without illumination |
|
65.510 |
Trinocular RZT microscope |
With PL stand without illumination |
|
65.550 |
Binocular RZB microscope |
With SF stand for incident and transmitted illumination |
|
65.560 |
Trinocular RZT microscope |
With SF stand for incident and transmitted illumination |
|
65.700 |
Binocular RZB head |
Head without stand |
|
65.710 |
Trinocular RZT head |
Head without stand |
|
65.720 |
Stereo head holder |
Height adjustable, for mounting of RZ binocular or trinocular stereo heads |
|
65.725 |
|
Weight 18 kg. to be used with stereo head holder 65.720 |
|
65.727 |
LT universal stand |
With bench clamp, to be used with stereo head holder 65.720 |
|
AE.1950 |
Positioning X-Y stage |
395 x 395 mm. ; translation X-7 360 x 260 mm. with ball bearings |
|
AE.1960 |
Round positioning table |
Tabletop can be positioned in all directions, 200 mm. diameter |
|
LE.1970 |
50 LED ring illuminator |
Working distance 55 to 120 mm. Adjustable light intensity. without supplementary lens, adaptor 65.868 is required with supplementary lens, adaptor 65.869 is required |
|
LE.1971 |
40 LED ring illuminator |
Working distance 25 to 75 mm. Adjustable light intensity. without supplementary lens, adaptor 65.868 is required with supplementary lens, adaptor 65.869 is required |
|
65.865 |
Fluorescent ring illuminator |
Fixed light intensity. without supplementary lens, no adaptor is required with supplementary lens, adaptor 65.869 is required |
|
LE.1863 |
Fluorescent 5200K ring illuminator |
Working distance 30 to 160 mm. Fixed light intensity. without supplementary lens, adaptor 65.868 is required with supplementary lens, adaptor 65.8679 is required |
|
LE.5209 |
20 W cold-light source |
With ‘flex & stay’ single arm fibre optic light guide |
|
LE.5210 |
100 W cold-light source |
Without light guides. Adjustable light intensity |
|
LE.5211 |
150 W cold-light source |
Without light guides. Adjustable light intensity |
|
LE.5213 |
Single arm glass fibre |
Gooseneck ‘flex & stay’ light guide, 4 mm. dia.x 500 mm. |
|
LE.5214 |
Two arm glass fibre |
Gooseneck ‘flex & stay’ light guide, 4 mm. dia.x 500 mm. |
|
LE.5215 |
Three arm glass fibre |
Gooseneck ‘flex & stay’ light guide, 4 mm. dia.x 500 mm. |
|
LE.5239 |
Ring light illumination |
With fibre optic light guide, 8 mm. dia. x 600 mm. (*) |
|
LE.5240 |
Ring light illumination |
With fibre optic light guide, 8 mm. dia. x 1000 mm. (*) |
(*) when a supplementary lens is used with a RZ stereo together with the ring light illuminator LE.5239 or LE.5240, a 65.869 adaptor is required. If no supplementary lens is used adaptor 65.868 is required.
Accessories:
|
Wide Field Eyepieces |
|
|
65.736 |
Pair of wide field eyepieces WF 10x/20 (standard) |
|
65.737 |
Pair of wide field eyepieces WF 15x/16 |
|
65.738 |
Pair of wide field eyepieces WF 20x/13 |
|
65.740 |
Pair of wide field eyepieces WF 25x/12 |
|
65.749 |
Wide field eyepieces WF 10x/20 with micrometer graticule 10 mm. / 100 parts. Adjustable lens |
|
65.750 |
Pair of eyecups for all eyepieces |
|
Supplementary Lenses and Adaptors for Illuminators |
|
|
65.753 |
Objective 0.4x, working distance 225 mm. |
|
65.754 |
Objective 0.5x, working distance 160 mm. |
|
65.755 |
Objective 0.75x, working distance 110 mm. |
|
65.757 |
Objective 1.5x, working distance 40 mm. |
|
65.758 |
Objective 2.0x, working distance 25 mm. |
|
65.867 |
Adaptor for LE.1863, required when using supplementary lenses |
|
65.868 |
Adaptor for LE.5239, LE.5240, LE.1970, LE.1971 and LE.1863, required when no supplementary lenses are used |
|
65.869 |
Adaptor for LE.5239, LE.5240, LE.1970, LE.1971 and LE.1863, required when using supplementary lenses |
|
Adaptors for camera |
|
|
65.818 |
23.2 mm. phototube for RZT trinocular head |
|
65.819 |
Adaptor for SLR camera with 2.5x photo eyepiece and T2 thread |
|
65.820 |
Adaptor for SLR camera with adjustable eyepiece. With 2.5x photo eyepiece and T2 thread |
|
Accessories for Cold-Light Sources |
|
|
LE.5222 |
Focusing head for mounting LE.5224 lens and filters. Suitable for ‘flex & stay’ and flexible light guides |
|
LE.5228 |
Focusing head identical to LE.5222 but with iris diaphragm for light intensity adjustment without altering the colour temperature |
|
LE.5223 |
Colour filter set (red/blue/green) for LE.5222 and LE.5228 |
|
LE.5224 |
Aspherical condenser lens for LE.5222 and LE.5228 |
|
LE.5231 |
Conversion filter KB12/80B for daylight film |
|
LE.5229 |
Polarisation filter for reducing reflections |
|
Miscellaneous |
|
|
65.871 |
Stage plate black/white, 94 mm. dia., for PL and SF stands |
|
65.872 |
Transparent glass stage plate, 87 mm. dia., for SF stand |
|
65.873 |
Transparent glass stage plate, 94 mm. dia., for SF stand |
|
65.895 |
Spare halogen bulb 6 Volt 10 Watt with reflector for incident illuminator for SF stand (65.550 and 65.560) |
|
65.896 |
Spare fluorescent bulb 5 Watt, 6400ºK for transmitted illumination for SF stand (65.550 and 65.560) |
|
65.960 |
Cabinet with handle and lock suitable for models RZ with PL stands (65.500 and 65.510) |
|
65.961 |
Cabinet with handle and lock suitable for models RZ with SF stands (65.550 and 65.560) |
|
|
|
|
SL.5208 |
Spare halogen bulb with reflector, 12 Volt, 20 Watt for LE.5209 |
|
SL.5219 |
Spare halogen bulb with reflector, 12 Volt, 100 Watt for LE.5210 |
|
SL.5230 |
Spare halogen “long-life” bulb with reflector, 12 Volt, 100 Watt for LE.5210 |
|
SL.5235 |
Spare halogen bulb with reflector, 15 Volt, 150 Watt for LE.5211 |
|
SL.1864 |
Spare bulb for LE.1863 |
|
AE.5227 |
Glass fuses 1 Amp, pack of 10 |