Dry Block Heaters
Labnet AccuBlock Mini Compact Digital Dry Bath for 12 x 1.5 ml. Tubes
Features:
- Accurate temperature control from ambient +5ºC to 100ºC in 0.1ºC increments
- Temperature uniformity / accuracy: < 0.2ºC / < 0.2oC
- Integral anodised aluminium block to hold 12 x 1.5 ml. tapered microcentrifuge tubes and has a thermometer well for temperature confirmation or calibration
- Precision LCD digital display
- AccuRack transfer rack included to facilitate the loading or unloading of all tubes simultaneously, improving efficiency. The AccuRack can stand on a bench to hold the tubes while they are prepared for loading and its four legs slip into slots on either side of the block without interference to location of the sample tubes. Alternatively tubes can be loaded and unloaded manually without the AccuRack
- Timer: 0 – 19 hours 59 minutes or continuous
- Built-in calibration modeallows end users to calibrate the bath as needed
- Dimensions: 140W x 120D x 60H mm.
- Weight : 1.3 kg.
- Electrical : 230V / 50-60 Hz
Ordering information :
D0100-230V |
Labnet AccuBlock Mini Digital Dry Bath, 12 x 1.5 ml., 230V, Ssupplied with 1 x AccuRack |
Benchtop control of sample temperature has never been this easy or economical. The MyBlock™ Mini digital dry bath fits almost anywhere and can even be used ‘on-the-go’ in cars, boats or wherever a 12V power source is available. Its simple touch pad control with digital display is designed for ‘set and walk away’ temperature selection and unrivalled accuracy. At less than 115 mm. wide, MyBlock™ Mini is truly the first personal block incubator.
- Compact, fits in the palm of your hand
- Exchangeable blocks, for tubes from 0.2ml. to 50ml.
- Hinged cover ensures temperature uniformity
- Digital temperature control
- Portable (optional 12V adaptor)
- Temperature range: ambient + 5°C to 100°C
- Temperature accuracy: ± 0.5°C
- Temperature increments: 0.1°C
- Temperature uniformity: ± 0.2°C
- Exterior dimensions: 105W x 150D x 115H mm.
- Weight: 1 kg.
- Electrical: 100 - 240V, 50 – 60 Hz*
* 12V vehicle power adaptor also available
Cat. Number
|
Description
|
BSH200-E-UK
|
MyBlock™ Mini digital dry bath with block lifter (blocks sold separately) |
Exchangeable blocks:
|
|
BSH100-02
|
Block for 40 x 0.2ml. tubes or 5 x PCR strips
|
BSH100-05
|
Block for 24 x 0.5ml. tubes
|
BSH100-15
|
Block for 15 x 1.5ml. tubes
|
BSH100-1520
|
Block for 15 x 1.5ml. or 2.0ml. tubes
|
BSH100-150
|
Block for 4 x 15ml. tubes (not compatible with clear cover) |
BSH100-500
|
Block for 2 x 50ml. tubes (not compatible with clear cover) |
Optional:
|
|
BSH100-A12
|
12V vehicle power adaptor
|

- Special thicker blocks guarantee excellent temperature stability
- Digital microprocessor control (PID) for highest accuracy
- A variety of interchangeable insert blocks
- CE certified
- Block combined with the close fit of the tubes for fast and efficient heat transfer
- Standard flat covers for protecting the user from accidentally touching a hot block and spitting tubes
- Safety features:
Temperature range
|
Ambient +5ºC to 150ºC
|
Timer
|
99 hours 59 minutes
|
Temperature accuracy
|
± 0.5ºC
|
Heating method
|
Cartridge heater, 2 x 150W
|
Capacity
|
1 block
|
Materials
|
Energy plate and sample block: aluminium
Inside and insulating side: stainless steel
|
Weight
|
3 kg. (without block)
|
Dimensions
|
200W x 270D x 130H mm.
|
Wattage
|
310W
|
Electrical
|
230V / 50-60 Hz
|
Cat. number
|
Description
|
|
ALB-H1
|
FINEPCR Model ALB-H1 Heating Thermoblock for 1 block, with CVH1-F flat cover, 230V (without block)
|
|
Accessories:
|
||
AB100-96
|
Block to hold 1 x 96-well PCR plate or 12 x 8 tubes strips
|
|
AB100-0548
|
Block to hold 48 x 0.5ml. microcentrifuge tubes
|
|
AB100-1524
|
Block to hold 24 x 1.5ml. microcentrifuge tubes
|
|
AB100-1516
|
Block to hold 16 x 15ml. conical tubes
|
|
AB100-508
|
Block to hold 8 x 50ml. conical tubes
|
|
JD100
|
Block extraction tool
|
|
CVH1-80
|
High cover for conical tubes blocks
|
|
Spare:
|
||
CVH1-F
|
Flat cover for ALB-H1
|
Labnet's AccuBlock digital dry baths provide users with digital performance and convenience at an analog price.
- Precise microprocessor control
- Broad temperature range, up to 150:C
- Large digital display
- Easy user calibration
- Single and dual block models
Useful for a variety of applications in molecular biology, histology, clinical, environmental and industrial settings, the units feature a broad temperature range and excellent uniformity. A microprocessor regulates the high wattage heater to provide precise, accurate control and rapid heating. The stainless steel block chamber ensures even transfer of heat from the heating element to the block.
Microprocessor control A microprocessor regulates the high wattage heaters in the baths to provide pre-cise, accurate control. The exact desired temperature is easily set using the arrow keys on the sloped control panel while values are shown on the large digital dis-play. No checking of a thermometer and readjusting temperature is necessary. The user calibration feature allows for easy calibration to in house standards when required. An RS232 port is provided for monitoring and recording temperature.
Both single and dual block units are available. Interchangeable blocks (sold separately) accommodate a wide variety of tubes, plates, blocks and slides. Each dry bath is supplied with a block lifter for convenient block removal.
Specifications:
- Temperature range: Ambient +5: to 150:C
- Temperature resolution: 0.1:C
- Temperature uniformity: ±0.2:C
- Temperature accuracy: ±0.3:C
- Temperature control: Microprocessor
- Chamber construction: Stainless steel
- Dimensions (W x D x H): 7.9 x 10.4 x 3.3 in./20 x 26.5 x 8.3 cm
- Weight: 4.8 lb/2.2 kg
- Electrical: 120V~, 50/60 Hz or 230V~, 50/60 Hz
Dry Bath Blocks
Designed for use with the AccuBlock dry baths, these blocks are supplied in a variety of formats to accept tubes from 0.2 to 50 ml as well as microplates and slides.
- Corrosion resistant, anodized aluminum
- Blocks for tubes from 0.2 ml to 50 ml, plates and slides
- Precision machined for a close fit and efficient heat transfer
- Solid block available for custom machining
Solid blocks are also available for custom machining. The blocks are made of high grade, nonporous aluminum and precision machined for a close fit. Anodizing adds corrosion resistance. Most blocks include a position for a thermometer and a threaded hole for use with the block lifter tool. The PopStopper accessory fits on the microtube blocks to keep tube lids from popping open during heating.
Ordering Information:
D1100-230V |
Single block capacity: |
|
D1200-230V |
Two block capacity |
|
D1101 |
Solid block for machining (no holes) |
|
D1102 |
Block, 48 x 0.2ml PCR tubes or 6 x 0.2ml |
|
D1102A |
Block, 24 x 2.0 ml tubes |
|
D1105 |
Block, 24 x 0.5 ml tubes |
|
D1105A |
Block, 24 x 1.5 ml tubes |
|
D1106 |
Block, 35 x 6 mm tubes |
|
D1110 |
Block, 20 x 10 mm tubes |
|
D1112 |
Block, 20 x 12 mm tubes |
|
D1113 |
Block, 20 x 13 mm tubes (12mm tubes also useable) |
|
D1115-TALL |
Block, 12 x 15 ml centrifuge tubes |
|
D1116 |
Block, 15 x 16 mm tubes |
|
D1120 |
Block, 6 x 20 mm tubes |
|
D1125 |
Block, 6 x 25 mm tubes |
|
D1150-TALL |
Block, 5 x 50 ml centrifuge tubes |
|
D1196-PCR |
Single Block, 96 well PCR plate, skirted or nonskirted (for single block unit only) |
|
D1296 |
Dual Block, 96 well microtitre plate or 4 slides (for dual block unit only) |
|
D1296-PCR |
Dual Block, 96 well PCR plate,skirted or nonskirted (for dual block unit only) |

- Special thicker blocks guarantee excellent temperature stability
- Digital microprocessor control (PID) for highest accuracy
- A variety of interchangeable insert blocks
- CE certified
- Block combined with the close fit of the tubes for fast and efficient heat transfer
- Standard flat covers for protecting the user from accidentally touching a hot block and spitting tubes
- Safety features:
Temperature range
|
Ambient +5ºC to 150ºC
|
Timer
|
99 hours 59 minutes
|
Temperature accuracy
|
± 0.5ºC
|
Heating method
|
Cartridge heater, 2 x 300W
|
Capacity
|
2 blocks
|
Materials
|
Energy plate and sample block: aluminium
Inside and insulating side: stainless steel
|
Weight
|
6 kg. (without blocks)
|
Dimensions
|
200W x 360D x 150H mm.
|
Wattage
|
610W
|
Electrical
|
230V / 50-60 Hz
|
Cat. number
|
Description
|
|
ALB-H2
|
FINEPCR Model ALB-H2 Heating Thermoblock for 2 blocks, with CVH2-F flat cover), 230V (without blocks)
|
|
Accessories:
|
||
AB100-96
|
Block to hold 1 x 96-well PCR plate or 12 x 8 tubes strips
|
|
AB100-0548
|
Block to hold 48 x 0.5ml. microcentrifuge tubes
|
|
AB100-1524
|
Block to hold 24 x 1.5ml. microcentrifuge tubes
|
|
AB100-1516
|
Block to hold 16 x 15ml. conical tubes
|
|
AB100-508
|
Block to hold 8 x 50ml. conical tubes
|
|
JD100
|
Block extraction tool
|
|
CVH2-80
|
High cover for conical tubes blocks
|
|
Spare:
|
||
CVH2-F
|
Flat cover for ALB-H2
|

- Special thicker blocks guarantee excellent temperature stability
- Digital microprocessor control (PID) for highest accuracy
- A variety of interchangeable insert blocks
- CE certified
- Block combined with the close fit of the tubes for fast and efficient heat transfer
- Standard flat covers for protecting the user from accidentally touching a hot block and spitting tubes
- Safety features:
Temperature range
|
Ambient +5ºC to 150ºC
|
Timer
|
99 hours 59 minutes
|
Temperature accuracy
|
± 0.5ºC
|
Heating method
|
Cartridge heater, 4 x 300W
|
Capacity
|
4 blocks
|
Materials
|
Energy plate and sample block: aluminium
Inside and insulating side: stainless steel
|
Weight
|
10kg. (without blocks)
|
Dimensions
|
335W x 360D x 150H mm.
|
Wattage
|
1200W
|
Electrical
|
230V / 50-60 Hz
|
Cat. number
|
Description
|
|
ALB-H4
|
FINEPCR Model ALB-H4 Heating Thermoblock for 4 blocks, with CVH4-F flat cover, 230V (without blocks)
|
|
Accessories:
|
||
AB100-96
|
Block to hold 1 x 96-well PCR plate or 12 x 8 tubes strips
|
|
AB100-0548
|
Block to hold 48 x 0.5ml. microcentrifuge tubes
|
|
AB100-1524
|
Block to hold 24 x 1.5ml. microcentrifuge tubes
|
|
AB100-1516
|
Block to hold 16 x 15ml. conical tubes
|
|
AB100-508
|
Block to hold 8 x 50ml. conical tubes
|
|
JD100
|
Block extraction tool
|
|
CVH4-80
|
High cover for conical tubes blocks
|
|
Spare:
|
||
CVH4-F
|
Flat cover for ALB-H4
|

- Special thicker blocks guarantee excellent temperature stability
- Digital microprocessor control (PID) for highest accuracy
- A variety of interchangeable insert blocks
- CE certified
- Block combined with the close fit of the tubes for fast and efficient heat transfer
- Standard flat covers for protecting the user from accidentally touching a hot block and spitting tubes
- Safety features:
Temperature range
|
Ambient +5ºC to 150ºC
|
Temperature accuracy
|
± 0.5ºC
|
Heating method
|
Cartridge heater
|
Capacity
|
1 block
|
Materials
|
Energy plate and sample block: aluminium
Inside and insulating side: stainless steel
|
Weight
|
4 kg. (without block)
|
Dimensions
|
148W x 230D x 155H mm.
|
Wattage
|
250W
|
Electrical
|
230V / 50-60 Hz
|
Cat. number
|
Description
|
ALB64
|
FINEPCR Model ALB64 Heating Thermoblock for 1 block, with CV64-F flat cover, 230V (without block)
|
Accessories:
|
|
AB90-0.2
|
Block to hold 64 x 0.2ml. microcentrifuge tubes (90 x 90 x 60H mm.)
|
AB90-0.5
|
Block to hold 49 x 0.5ml. microcentrifuge tubes (90 x 90 x 60H mm.)
|
AB90-1.5
|
Block to hold 36 x 1.5ml. microcentrifuge tubes (90 x 90 x 60H mm.)
|
AB90-12
|
Block to hold 36 x 12 mm. dia. test tubes (90 x 90 x 60H mm.)
|
AB90-13
|
Block to hold 25 x 13 mm. dia. test tubes (90 x 90 x 60H mm.)
|
AB90-15
|
Block to hold 25 x 15 mm. dia. test tubes (90 x 90 x 60H mm.)
|
AB90-16.5
|
Block to hold 20 x 16.5 mm. dia. test tubes (90 x 90 x 60H mm.)
|
AB90-18
|
Block to hold 20 x 18 mm. dia. test tubes (90 x 90 x 60H mm.)
|
AB90-C15
|
Block to hold 9 x 15ml. conical tubes (90 x 90 x 80H mm.)
|
AB90-C50
|
Block to hold 5 x 50ml. conical tubes (90 x 90 x 80H mm.)
|
JD90
|
Block extraction tool
|
GB90
|
Ball bath (zinc ball)
|
CV64-80
|
High cover for test tube (115W x 115D x 80H mm.)
|
Spare:
|
|
CV64-F
|
Flat cover for ALB64 (115W x 115D x 10H mm.)
|

- Special thicker blocks guarantee excellent temperature stability
- Digital microprocessor control (PID) for highest accuracy
- A variety of interchangeable insert blocks
- CE certified
- Block combined with the close fit of the tubes for fast and efficient heat transfer
- Standard flat covers for protecting the user from accidentally touching a hot block and spitting tubes
- Safety features:
Temperature range
|
Ambient +5ºC to 150ºC
|
Temperature accuracy
|
± 0.5ºC
|
Heating method
|
Cartridge heater
|
Capacity
|
1 blocks
|
Materials
|
Energy plate and sample block: aluminium
Inside and insulating side: stainless steel
|
Weight
|
7 kg. (without blocks)
|
Dimensions
|
238W x 230D x 155H mm.
|
Wattage
|
490W
|
Electrical
|
230V / 50-60 Hz
|
Cat. number
|
Description
|
ALB128
|
FINEPCR Model ALB128 Heating Thermoblock for 2 blocks, with CV128-F flat cover, 230V (without block)
|
Accessories:
|
|
AB90-0.2
|
Block to hold 64 x 0.2ml. microcentrifuge tubes (90 x 90 x 60H mm.)
|
AB90-0.5
|
Block to hold 49 x 0.5ml. microcentrifuge tubes (90 x 90 x 60H mm.)
|
AB90-1.5
|
Block to hold 36 x 1.5ml. microcentrifuge tubes (90 x 90 x 60H mm.)
|
AB90-12
|
Block to hold 36 x 12 mm. dia. test tubes (90 x 90 x 60H mm.)
|
AB90-13
|
Block to hold 25 x 13 mm. dia. test tubes (90 x 90 x 60H mm.)
|
AB90-15
|
Block to hold 25 x 15 mm. dia. test tubes (90 x 90 x 60H mm.)
|
AB90-16.5
|
Block to hold 20 x 16.5 mm. dia. test tubes (90 x 90 x 60H mm.)
|
AB90-18
|
Block to hold 20 x 18 mm. dia. test tubes (90 x 90 x 60H mm.)
|
AB90-C15
|
Block to hold 9 x 15ml. conical tubes (90 x 90 x 80H mm.)
|
AB90-C50
|
Block to hold 5 x 50ml. conical tubes (90 x 90 x 80H mm.)
|
JD90
|
Block extraction tool
|
GB90
|
Ball bath (zinc ball)
|
CV128-80
|
High cover for test tube (230W x 115D x 80H mm.)
|
Spare:
|
|
CV128-F
|
Flat cover for ALB128 (230W x 115D x 10H mm.)
|
Boekel Dry Bath Incubators, 4 Blocks Capacity
Features:
- Available in analogue and digital control models
- Temperature range: ambient +5°C to 130°C (120°C for analogue model)
- Temperature increments of 0.1°C for digital model
- Temperature uniformity: ± 0.25°C for digital model and ± 0.50°C for analogue model @ 37°C
- Temperature stability: ± 0.2°C for digital model and ± 0.45°C for analogue model @ 37°C
- PID microprocessor controlled temperature selection with large LED display for digital model
- Blocks are interchangeable between analogue and digital models
- Amber pilot light for analogue model
- Supplied with block extractor rod
- 13 interchangeable blocks to choose from
- Power: Analogue - 300W; Digital – 380W
- Dimensions: Analogue - 260W x 286L x 89H mm.;
Digital – 203W x 249L x 89H mm.
- Weight: Analogue – 2.4 kg.; Digital – 2.0 kg.
- 2 year warranty
Ordering information:
Cat. Number |
Description |
112004-2 |
Boekel Analogue dry bath incubator, 4 block capacity (see below) |
113004-2 |
Boekel Digital dry bath incubator, 4 block capacity (see below) |
InterchangeableBlocks: (all 76W x 95L x 51H mm. except for 110051 and 110096) |
|
110006 |
Block to hold 35 x 6 mm. diameter tubes |
110010 |
Block to hold 20 x 10 mm. diameter tubes |
110013 |
Block to hold 20 x 13 mm. diameter tubes |
110016 |
Block to hold 12 x 16 mm. diameter tubes |
110020 |
Block to hold 6 x 20 mm. diameter tubes |
110025 |
Block to hold 6 x 25 mm. diameter tubes |
110035 |
Block to hold 3 x 25 mm., 5 x 13 mm. and 6 x 6 mm. diameter tubes |
110040 |
Block to hold 24 x 1.5ml. microtubes |
110045 |
Block to hold 24 x 0.5ml. microtubes |
110048 |
Block to hold 48 x 0.2ml. tubes |
110051 |
Block to hold 1 x 96-well microplate (block dimensions: 148 x 95 x 44 mm.) |
110096 |
Block to hold 1 x 96-well 0.2ml. microplate, strips or tubes (block dimensions: 153 x 96 x 25 mm.) |
110099 |
Block, 24 x 1.5 ml. ‘Dolphin’ tubes |
110004LID |
Acrylic plastic cover for 4 block dry bath incubator |
Call... | Enquire... |
---|---|
Call Progen Scientific to discuss your requirements on 0208 542 2283 | Click here to make an enquiry about a Dry Block Heaters |