Boeco Spectrophotometers

home  -   contact  -   site map
 

Boeco Spectrophotometers

Models S-20 Vis & S-22 UV/Vis

  • Wavelength ranges:
    • 320 - 1000 nm (S-20)
    • 198 - 1000 nm (S-22)
  • Bandwidths:
    • 8 nm (S-20)
    • 6 nm (S-22)
  • In-built wavelength calibration
  • Automatic O%T setting during all calibration routines
  • Dual display - wavelength & photometric result
  • Full interfacing capability
  • (bi-directional RS 232 interface)
  • Versatile sampling system
  • Simple operation
  • Ideal for Routine Analysis
  • First quality at affordable prices
  • Manufactured under ISO 9000 norms
  • CE mark for electromagnetic compatibility

The BOECO Model S-22 has a unique xenon lamp which has the advantage of offering a broad spectral source with extended life. This enables the running costs for the S-22 to be minimised over the lifetime of the spectrophotometer, since there are no deuterium and tungsten lamps to replace.

  • Single lamp with guaranteed 3 year life time
  • Self calibrating lamp at 3 wavelengths
  • 10 times more UV light energy
  • Blazed holographic grating

Specifications

S-20 Vis

S-22 UV/Vis

Wavelength:

Range

320 - 1000 nm

198 - 1000 nm

Resolution

1nm

1nm

Accuracy

± 2 nm

± 2 nm

Bandwith

8 nm

6 nm

Absorbance:

Range

-0.300 to 1.999 A

-0.300 to 1.999A

Resolution

0.1 %

0.1 %

Stray Light

<0,5% @ 340 nm

<0.5% @ 340 nm

Photometric Accuracy

± 1%

± 1%

Concentration:

Range

-300 to 1999 Concentration

-300 to 1999 Concentration

Resolution

0.1 / 1

0.1 / 1

Units

ppm, mg/l, g/l, M, %, blank

ppm, mg/l, g/l, M, %, blank

Factor

0 to 999.9, 1000 to 9999

0 to 999.9, 1000 to 9999

Photometric Noise Levels

<1%

<1%

Photometric Stability

1%/Hour after warm-up

1%/Hour after warm-up

Readout

Custom Liquid Crystal Display

Custom Liquid Crystal Display

Outputs

Analog (0 to 1999mV) /

RS232 serial port

Analog (0 to 1999mV) /

RS232 serial port

Light Source

Tungsten Halogen 20W 12V

Xenon Lamp module

Input Voltage

115/230V AC -20% +10%

115/230V AC -20% +10%

Input Power

<50W

<50W

Size

365(W)x272(D)x166(H) mm

365(W)x272(D)x166(H) mm

Weight

6 kgs

6 kgs



Accessories

BOE 632 001

EU Sipper Pump, 220 V

BOE 632 031

US Sipper Pump, 110 V

BOE 630 020

Test Tube Block (13mm diameter)

BOE 630 021

Test Tube Block (25mm diameter)

BOE 630 022

Test Tube Block (16mm diameter)

BOE 648 001

Water heated single Cell Block

BOE 634 001

4 position cell holder

BOE 630 005

20 - 100mm adjustable Cell holder

BOE 630 004

10 x 10mm Cell holder

BOE 012 075

Tungsten Halogen Lamp (model S-20)

BOE 012 094

Xenon Lamp module (model S-22)

BOE 050 002

Serial interface set up software on 3.5' disc

BOE 035 088

Calibration Set Visible (S-20)

BOE 035 091

Calibration Set UV/Visible (S-20/22)



Cells & Cuvettes

HEL 6030-OG/10

Macro Cell without lid

optical glass 360 - 2500 nm

10 mm light path

HEL 6030-UV

Macro Cell, without lid

Quartz HERASIL 230 - 2500 nm

10 mm light path

HEL 100-QS/10

Macro Cell, with PTFE lid

Quartz SUPRASIL 200 - 2500 nm

10 mm light path

HEL 6040-OG

Semi-Micro Cell, without lid

optical glass 360 - 2500 nm

10 mm light path

HEL 6040-UV

Semi-Micro Cell, without lid

Quartz HERASIL 230 - 2500 nm

10 mm light path

BOE 2711110

Disposable Macro Cuvettes, PS

10 mm light path, pack of 100 pcs.

BOE 2712120

Disposable Semi-Micro Cuvettes, PS

10 mm light path, pack of 100 pcs.

BOE 998183

Disposable UV Semi-Micro Cuvettes,

PS, wavelength as from 220 nm

10 mm light path, pack of 100 pcs.


BOE 8636001 Boeco Model S-30 Life Science Analyser

(Spectrophotometer), Wavelength range 198 - 1000nm.

Resolution: 1nm. Accuracy: +/- 2nm. Bandpass: 5nm.

Light source: Xenon lamp (guaranteed lamp life 3 years)

Dedicated software for DNA/RNA and protein

chemistry 260/280, 260/230. Ideal for monitoring

cell growth at 600nm.

Small footprint and weight (6 Kg.)

Self-calibrating. Purity scan.

Supplied with 8 x 300ul. UV plastic cuvettes, cell holder,

mains lead and instruction manual

BOECO S-30 Life Science Analyser

  • Pre-programmed for DNA Analysis
  • DNA Purity Scan
  • Established Protein Methods Pre-Loaded
  • Standard UV/vis Spectrophotometer Functions

 

The BOECO S-30 has been designed specifically for the scientist whose primary interest is the study of DNA and Protiens. Optimised for low volume analysis, the BOECO S-30 is capable of determining DNA levels as low as 70ng with samples as low as 50ul using special cuvettes and the micro-cuvette holder.

All routinely used DNA calculations are pre-programmed into BOECO S-30. It will automatically calculate purity ratios at 260/280nm or 260/230nm both with an optional background correction wavelength (default at 320nm).

Concentrations of ssDNA, dsDNA, RNA and Oligonucleotides are clearly displayed on the large multi-function LCD display. In addition a 100nm purity scan may be run to clearly show the status of any samples.

The on-board software enables all the common protein measurement methodologies to be run directly with the minimum set-up time. Included are the Bradford, Biuret, BCA, Lowry, Biccinchonic and direct UV methods, standard settings can be used immediately or modified and stored for future use.

Where BOECO S-30 is used in a multi-user or unskilled user environment a Supervisor Security mode can be activated which looks all the set-up options without the entry of a pin code.

As well as these general life science applications BOECO S-30 can also be used as a standard UV/vis spectrophotometer with Absorbance and Transmission readings being given across the wavelength range from 198 to 1000nm.



 
Search
Search Site:
Make an Enquiry








Brochures
Progen Focus 2008 Download Adobe Acrobat Reader
Food, Feed and Environmental Analysis Equipment from Progen Scientific Progen Five Star Capital Equipment
To view the brochures you will need to have Acrobat Reader
 
Site Build and Hosting by Wizzy Design Ltd.  |   Design By Website Optimisation  |   Powered By Apex CMS ©
Boeco Spectrophotometers © Progen Scientific Ltd. 2008. All Rights Reserved.