Cecil Spectrophotometers

home  -   contact  -   site map
 

Cecil Spectrophotometers

Series 1000

CE1011

Visible wavelength range 325 - 1000nm, 8nm. bandpass, single beam

CE1021

UV / Visible wavelength range 200 - 1000nm., 8nm. bandpass, single beam

Aurius Series

CE2011

Aurius Visible wavelength range 325 - 1000nm., 4nm. bandwidth, single beam, (note: scanning capability is an optional extra)

CE2031

As per CE2011 but with integral printer

CE2021

Aurius UV / Visible wavelength range 190 - 1000nm., 4nm. bandwidth

CE2041

As per CE2021 but with integral printer

CE2021D

Special version of CE2021 for tablet dissolution applications

CE2041D

Special version of CE2041 for tablet dissolution applications

Super Aurius Series

CE3021

Super Aurius UV / Visible wavelength range 190 - 1000nm., 1.8nm. bandwidth, single beam, scanning

CE3041

As per CE3021 but with integral printer

CE3021D

Special version of CE3021 for tablet dissolution application

CE3041D

Special version of CE3041 for tablet dissolution application

Aquarius Series

CE7200

Aquarius UV / Visible wavelength range 190 - 900nm., 2nm. bandwidth, double beam, scanning, fully symmetrical optics

CE7400

Aquarius UV / Visible wavelength range, 190 - 1100nm., 2nm. bandwidth, double beam, scanning, fully symmetrical optics

CE7500

Aquarius UV / Visible wavelength range 190 - 1100nm., variable bandwidth 0.5, 1, 2 and 4nm., double beam, scanning, fully symmetrical optics

Super Aquarius

CE9200

Super Aquarius UV / Visible wavelength range 190 - 800nm., 1.8nm. bandwidth, double beam, scanning, fully symmetrical optics. Software includes 1st. - 4th. derivatives

CE9500

Super Aquarius UV / Visible wavelength range 190 - 900nm., variable bandwidth 0.5, 1, 2 and 4nm., double beam, scanning, fully symmetrical optics, turbid sample optics and turbid sample holder. Software includes 1st. - 6th. derivatives

GeneQuest DNA/RNA Analyser

CE2301

GeneQuest Analyser wavelength range 190 - 370nm., 4nm. bandwidth, single beam, includes ultra-microcell holder.

NOTE: Additional internal filters required for Bradford (595nm.) and 600nm. assays

CE2302

As per CE2301 but with integral printer

BioQuest and BioAquarius Series

CE2501

BioQuest wavelength range 190 - 1000nm., 4nm. bandwidth, single beam, scanning. Includes 10mm. cell holder and standard software includes bio-analysis, kinetics, curve fit, protein assay, ratioing and method storage

CE2502

As per CE2501 but with integral printer

CE7250

BioAquarius wavelength range 190 - 900nm., 2nm. bandwidth, double beam, scanning. Includes 10mm. cell holder and standard software includes bio-analysis, kinetics, curve fit, protein assay, ratioing and method storage

AquaQuest (Water Analysis) Series

CE4001

AquaQuest Water Analysis, visible wavelength range 325 - 1000nm., 4nm. bandwidth, single beam. Includes 10mm. cell / 16mm. tube holder. Standard software includes curve fitting, ratioing, peak seek, method storage and water analysis.

CE4003

As per CE4001 but with integral printer

CE4002

AquaQuest Water Analysis, UV / Visible wavelength range 190 - 1000nm., 4nm. bandwidth, single beam. Includes 10mm.cell / 16mm. tube holder. Standard software includes curve fitting, ratioing, peak seek, method storage and water analysis.

CE4004

As per CE4002 but with integral printer

DietQuest (Food and Beverage) Series

CE2410

DietQuest Visible wavelength range 325 - 1000nm., 4nm. bandwidth, single beam with integral printer and pre-programmed for food and beverage analyses (Note: scanning capability is an optional extra)

CE3410

DietQuest UV / Visible wavelength range 190 - 1000nm., 1.8nm. bandwidth, single beam, scanning with integral printer and pre-programmed for food and beverage analyses

CE7210

DietQuest UV / Visible wavelength range 190 - 900nm., 1.8nm. bandwidth, double beam, scanning and pre-programmed for food and beverage analyses

ReflecaScan Reflectance Spectrophotometers

CE3055

ReflectaScan UV /Visible wavelength range 190 - 1000nm., 4nm. bandwidth, single beam, scanning with integral printer

CE3075

Specular and opthalmic lens reflectance accessory

CE3073

Integrating sphere diffuse reflectance accessory

CE3077

Transmittance accessory for lens

PharmaQuest Dissolution Systems

CE3790

Tablet Dissolution Tester

CE9260

UV / Visible wavelength range 190 - 800nm., 1.8nm. bandwidth, double beam, dissolution sample compartment with flow tube port, 8 position cell changer, 8 cell holder.

CE7260

UV / Visible wavelength range 190 - 900nm., 1.8nm. bandwidth, double beam dissolution compartment with flow tube port, 8 position cell changer, 8 cell holder.

CE3021D

UV / Visible wavelength range 190 - 1000nm., 1.8nm. bandwidth, single beam, dissolution sample compartment and lid, flow tube port, 8 position cell changer, 8 cell holder.

CE3791

Peristaltic Pump

CE3792

Dissolution software

Systems:

System 1

CE3790, CE7260, CE3791, CE3792 and all items to complete the system. Requires flow cellS and a PC

System 2

CE3790, CE3021D, CE3791, CE3792 and all items to complete the system. Requires flow cells and a PC

System 3

CE3790, CE9260, CE3791, CE3792 and all items to complete the system. Requires flow cellS and a PC


 