Bandelin ultrasonic homogenisers
Ultrasonic homogenizers are used in laboratories, hospitals and in industry for scientific experiments, analysis and also in pilot or small-lot production.
Sonopuls Ultrasonic Homogenizers
The AMPLICHRON system guarantees a constant amplitude independently from changing conditions within the sample. It also ensures reproducible results for process validation. S
Permanent control of ultrasound irradiation as well as indication of wear of the probe.
- Pulsation:
- Built-in timer:
- Processing frequency: 20 kHz uniform sonic waves
- Switching ON / OFF:
- Compact construction:
- Foil keypad:
- Fail-safe during continuous operation and idling
- RFI-proofed and CE-marked, also as medical device compliant to the directive for in-vitro diagnostics 98/79/EG
How to select the proper unit
Power output in watt should not be the only criterion for selecting an ultrasonic homogenizer. This value only indicates the power of the HF-generator but not the energy delivered to the sample. The amplitude at the radiating surface of the probe is the determining factor for the evaluation of the irradiation result while taking into consideration the volume of the sample.
SONOPULS ultrasonic homogenizers produce with the same electric power higher amplitudes than other models in the market thanks to an ideal integration of all components.
See also Applications of Ultrasonic Homogenisers.
Approximate values of life span
When operating in the continuous mode (100 % amplitude setting, no pulsation) in aqueous media and not exceeding more than 1 mm probe erosion at the irradiation surface the following approximate values are to be considered:
|
probes |
HD 2070/3080 |
HD 2200/3200 [h] |
|
MS 72 |
3 |
1 |
|
MS 73 |
6 |
2 |
|
KE 76 |
90 |
30 |
|
TT 13 |
330 |
110 |
|
TT 19 |
- |
280 |
|
TT 25 |
- |
480 |
SONOPULS Mini20 Handheld Ultrasonic Homogeniser
Features:
- Fast handheld operation
- Ready to operate for volumes from 0.5ml. to 25ml. (from 0.1 to 10ml. with optional MS 1.5 microtip probe
- Unit consists of: HF generator GM mini20, ultrasonic converter UW mini20 and titanium microtip probe MS 2.5 (2.5 mm. diameter)
Specifications:
|
HF generator
|
GM mini20
|
|
Dimensions
|
250 x 256 x 154 mm.
|
|
Weight
|
2.0 kg.
|
|
Mains supply
|
230 V, 50/60 Hz
|
|
Converter
|
UW mini20
|
|
Dimensions
|
approx. 50 mm. diameter x 160 mm. long
|
|
Weight
|
270g.
|
|
Available titanium probes
|
1.5 mm. or 2.5 mm. diameter
|
|
Cat. number
|
Description
|
|
3665
|
Sonopuls mini20 consists of: HF generator GM mini20, ultrasonic converter UW mini20 and titanium microtip probe MS 2.5 (2.5 mm. diameter)
|
|
3639
|
Titanium microtip probe MS 1.5, 1.5 mm. diameter, for volumes 0.1 to 10ml.
|
|
3652
|
Titanium microtip probe MS 2.5, 2.5 mm. diameter, for volumes 0.5 to 25ml.
|
Sonopuls HD 2070
For volumes from 2 ml to 200 ml
Ready-to-operate basic equipment for volumes from 2 ml to 50 ml with generator GM 2070, ultrasonic converter UW 2070, stepped standard horn SH 70 G and microtip MS 73, 3 mm diameter. 70 W HF-output.
Specifications:
- Dimensions mm 257 x 180 x 115
- Weight kg 2,5
- Mains supply 230 V~, 50/60 Hz, optionally with voltage selector for 115 V~, 50/60 Hz
- Converter UW 2070
- Dimensions mm Ø / dia.70 x 120
- Weight kg 1,0
- Available titanium probes Ø mm 2, 3, 6, 13
Sonopuls HD 2200
For volumes from 20 ml to 1000 ml
Ready-to-operate basic equipment for volumes from 20 ml to 900 ml with generator GM 2200, ultrasonic converter UW 2200, booster horn SH 213 G and titanium flat tip TT 13 of 13 mm diameter. 200 W HF-output.
Specifications:
- Dimensions mm 257 x 180 x 115
- Weight kg 2,5
- Converter UW 2200
- Dimensions mm Ø / dia. 70 x 120
- Weight kg 1,0
- Available titanium probes Ø mm 2, 3, 6, 13, 19, 25
Ordering Information:
|
Cat. 2450 |
Bandelin Sonopuls HD2070 ultrasonic homogeniser for volumes of 100ul. to 50ml., standard set with generator GM 2070, ultrasonic converter UW 2070. standard horn SH 70 G, microtip MS 73 (dia. 3mm. / 1/8"), 70 W HF-output |
|
|
Cat. 2530 |
Bandelin Sonopuls HD 2200 ultrasonic homogeniser for volumes of 5ml. to 900ml., standard set with generator GM 2200, ultrasonic converter UW 2200, booster horn SH 213 G, titanium flat tip TT 13 (dia. 13mm. / ½"), 200 W HF-output |
Probes
Probes made of titanium alloy (Ti-6Al-4V) transmit mechanical longitudinal waves into the sample. They are thermo-resistant, can be treated in autoclaves and are resistant to corrosive media. Sample volume, diameter of the processing vessel and the required amplitude determine the selection of the unit and the type of probe. The higher the amplitude, the more intense the sonication.
Extended probes VS 70 T / 200 T especially used for sonication of ceramic suspensions or when preparing samples for grain size analysis.
Probe extensions
- VS made of titanium alloy (Ti-6Al-4V), recommended for long-necked vessels.
- VS 70 between SH 70 G / 213 G and TT 13 (for HD2070/2200/3080/3200)
- VS 200 between SH 225 G and TT 25 (for HD2200/3200)
Silica glass probes
- GS for connection to HD 2070/3080 with special horn SH 70 GQ.
For application in food analysis, pharmacy or environmental analysis. No intrusion of metal particles and boron compounds - ideal or trace analysis. High chemical and temperature shock resistance, no electric conductivity.
Spiral probe
- WS 8, dia. 8 mm, made of titanium alloy (Ti-6Al-4V), with special horn SH 200 W, for connection to HD 2200/3200.
For gentle use in slim reaction vessels. Lateral irradiation. Long life through low wastage.
Standard and booster horns
Standard and booster horns (Ti-6Al-4V) are furnished with a thread for replaceable probes. With exterior thread to connect various vessels.
Solid booster horn
- DH 13 G with diamond coating on the radiating area; lifetime is thirty times longer than usually.
Flow-through standard and booster horns
- FZ 5 G and FZ 7 G to prepare stable mix tures of non-mixable or hardly mixable liquids (oil-in-water) by direct intrusion of pre-mixed samples into the cavitation field. In combination with flow-through cell DG 4 G the continuous treatment of 2 different media and parallel tempering is possible.
- Material: Ti-6Al-4V
Adapters
Sleeve adapters made of PTFE for tight mounting on stand ard ground glass vessels.
-
NA 29 G for NS 29/32 for SH 70/213 G
-
NA 45 G for NS 45/40 for SH 70/213/219/225G
- GA 3 G threaded adapter made of stainless steel with external thread M 40 x 1 for SH 70/213/219/225 G
Direct processing
Processing vessel, stainless steel
- DG 4 G for high-volume flow-through processing like emulsifying, dispersing or homogenizing, up to 30 l/h (for HD2070/2200/3080/3200).
- KG 4 G, closed vessel with cooling jacket (for HD2070/2200/3080/3200).
Processing volume about 65 ml.
Indirect processing
- Cup Horn BB for indirect irradiation with high energy. No contamination from cavitation erosion. No aerosoling with pathogenic or hazardous materials. For HD2070/3080.
- BB 6: temperature regulation with circulating liquid coolants. For HD2200/3200.
- Microtube holder EH 6 for use in BB 6. Up to 6 samples can be treated simultaneously. Pressure plate holds tubes in place. No floating of cups. For HD2200/3200.
- Cup booster BR 30 for high-intensive irradiation of smallest and sensitive sample volumes, e.g. cleaning of radioactively contaminated seeds, cell disruption or treatment of pathogens and toxic material. No cross-contamination or sample loss. Flow-through cooling liquid avoids rise of temperature. For HD2070/2200/3080/3200.
- Inset basket BK 30 for intensive cleaning of small parts in BR 30. For HD2070/2200/3080/3200.
- Microtube holder EH 3 for use with BR 30. Up to 3 samples can be treated simultaneously. 2 exchangable discs with diameters 8,5 or 11,5 mm. For HD2070/2200/3080/3200.
Accessories
Stand
- Stainless steel stand HG 5 with lab clamp, for safe fixing of ultrasonic converter. For HD2070/2200/3080/3200.
Sound proof boxes
Sound proof box reduces noise level. Inlets at rear side for gas supply or flow-through irradiation. Clear acrylic glass door permits observation of process. For HD2070/2200/3080/3200.
- LS 4 noise reduction in dB-AU: 10.
- LS 6 with height adjustable stand. Noise reduction in dB-AU: 20.
New: For indirect processing with BR 30, BB 6 or BB 2 G turn the box by 180°. Ultrasonic converter UW is fixed safely by special clamp. Support UG 6 is required.
- Distance tube AH 6 to be directly clamped into the closure of the LS 6 for direct sonication with long probes (MS 72/73, KE 76, VS 70 with TT 13, VS 200 with TT 25, VS 70 T, VS 200 T and GS..)
Remote control
Foot switch remote control: For easy switching ON/OFF of the HF-generator. With 3 m cable.- WINPULS remote control: For process control with PC for operation systems Win 2000 und WIN XP with different additional functions like test logging and comfortable data storage. (up to 99 storages). Set composed of WINPULS-Software and infrared adapter IR 1 for interface RS 232.
Temperature sensor
- TM100 for measuring of sample temperature from 0 up to 120 °C.