Laminar Air Flow Cabinets
HEPA filters are integral to laminar air flow cabinets. The European standard EN 1822 has superseded all national standards such as BS 3928, DIN 24184 or AFNOR NF X44-013. Telstar supply EN 1822 HEPA filters to all their cabinets.
If you are working with pathogens - you need to use a special type of laminar air flow cabinet, which is the Biological Safety Cabinets - see our Buyers Guide for this product line.
If you are working with Dangerous chemicals do not use laminar air flow - HEPA filters do not filter fumes - see our Fume Cupboards Buyers Guide.
| Call... | Enquire... |
|---|---|
| Call Progen Scientific to discuss your requirements on 0845 430 8555 | Click here to make an enquiry online about laminar air flow cabinets. |
There are different configurations of Laminar Air Flow Cabinets:
1) Horizontal Laminar Air Flow Cabinets - Telstar H100 series
|
Medical - Microbiology, Pharmacy, IVF Electronics - Dust elimination Food - QC labs, Microbiology Pharmaceutical - Clean air applications Nanotechnology |
This Product is designed to give maximum product protection. The air is drawn in from the top via a pre-filter. This removes larger particles giving longer life to the HEPA filter. The air then moves into the plenum (an enclosed space in which the air pressure is higher than outside) and from there to the outside through the HEPA filter
|
All models are supplied with working area Class 10 as defined by U.S.Fed. Std. 209 and B.S. 5295. |
Progen supply Telstar Horizontal Air Flow Cabinets
Things to consider when considering purchase:
Horizontal Laminar Air Flow Cabinets give only Product Protection. If any operator protection is needed these are not suitable.
Air is blown horizontally at the operator.
If a large piece of equipment is enclosed in the cabinet this will obstruct air from immediately in front of it. In this case a vertical flow unit may be preferable. See below.
Internal Size:
- Telstar MINI H Width 745mm
- Telstar AH-100 Width 1200mm
- Telstar MH-100 Width 1505mm
- Telstar BH-100 Width 1810mm
Benefits of the Telstar H-100 range:
- High Quality Steel construction
- Filter Change from inside the cabinet
- Stainless Steel work-surface
- Removable and U.V. resistant tempered glass sidewalls
- Optional UV Light
- Fluorescent Lighting
- Electrical power socket inside the cabinet
- Quality Control Certification for every cabinet with test results according to International Standards.
2) Vertical Laminar Air Flow Cabinets - Telstar V-100 and V30/70 series
There are two main types of Vertical Laminar Air Flow Cabinets
100% Downflow - Telstar V-100
This type of Cabinet draws air in through the top of the unit through a pre-filter, through a plenum and vertically down over the work-surface and past the lap of the operator. This gives 100% product protection.
It has the advantage of not pushing air into the face of the operator as in a horizontal laminar flow cabinet and also large pieces of equipment do create non-clean zones.
The operator has to work through a 200mm gap at the front. This is essential if full laminarity of the air is required.
30/70 Airflow - Telstar V30/70
This type of cabinet gives both product protection and a degree of operator protection.
The airflow is similar to that of a Class II Biological Safety Cabinet. It does not pass the requisite standards though and must not be used with pathogens!!
|
30% Exhausted 30% Drawn in front grille Creates a curtain of air between operator and product |
This unit has an exhaust HEPA filter ensuring all air passing through the cabinet is filtered before release into the environment
Progen Supply Telstar Vertical Air Flow Cabinets
Things to consider when considering purchase:
Do you need any operator protection? If yes - choose the V-30/70
Laboratory benching must be able to take weight of unit - typically 100-200Kg
Unit must not overhang benching - Units are top heavy - all the fans are above the work-surface
Internal Size:
- Telstar PV-100 Width 772mm
- Telstar AV-100 Width 1230mm
- Telstar BV-100 Width 1535mm
- Telstar CV-100 Width 1840mm
- Telstar PV-30/70 Width 772mm
- Telstar AV-30/70 Width 1230mm
- Telstar BV-30/70 Width 1535mm
- Telstar CV-30/70 Width 1840mm
Benefits of the Telstar V-100 and V-30/70 ranges:
- All models are supplied with working area CLASS 10 as defined by U.S.
- Fed. Std. 209 a B.S. 5295.
- High Quality Steel construction
- Filter Change from inside the cabinet
- Polished stainless steel working surface divided in
- three parts easily removable for sterilizing.
- Removable side walls and front window with gas
- springs, both made of U.V. resistant tempered glass.
- Optional UV Light
- Fluorescent Lighting
- Electrical power socket inside the cabinet
- Quality Control Certification for every cabinet with test results according to International Standards
Telstar Mini V PCR Laminar Air Flow Cabinets
Telstar have now produced a specific small personal Laminar Flow Cabinet designed for the explosion in PCR work now performed in so many laboratories.
|
Built in UV Light Small footprint Internal socket |
| Call... | Enquire... |
|---|---|
| Call Progen Scientific to discuss your requirements on 0845 430 8555 | Click here to make an enquiry online about laminar air flow cabinets. |
See our range of laminar air flow cabinets
See our other buyer's guides

Typical Applications:
70% Re-circulated
Fully Exhausted Air