Prestige Autoclaves
2100 Classic Prestige Autoclave
The 2100 Classic offers the most cost effective solution for the world’s preferred method of sterilization
Recommendation
Steam sterilization, or autoclaving, is the preferred method for eliminating the risk of cross

infection through contaminated instruments and the only one recommended throughout the world by healthcare professionals including the W.H.O (World Health Organisation) and C.D.C (Centre for Disease Control).
Evolution
Stylish aesthetics, together with a host of enhanced features, build on the successful attributes of the original Series 2100 range, to ensure the 2100 ‘Classic’ perfectly complements today’s modern clinics and the exacting needs of the healthcare professional.
Assurance
Prestige Medical, as an ISO 9001 / EN46001 accredited company ensures all products including the 2100 Classic have been designed to the latest international standards for safety and performance and are fully CE marked to the Medical Devices Directive 93/42/EEC.
Design
Light, compact and portable.
A simple one step operation starts the automatic cycle.
Light sequence indicators show ‘Power to Unit’ - ‘Cycle in Progress’ - ‘Sterilization in Progress’ - ‘Cycle is Successful’ or ‘Cycle has Failed’
An interlock system prevents the lid from being removed whilst pressure remains in the vessel.
A two stage ‘over pressure’ protection system incorporates a calibrated Pressure Release Valve and a Gasket Offset Device.
An extended life ‘green’ gasket lasts in excess of 600 cycles.
Electronic detectors turn off the power if there is insufficient water.
Optional temperature and pressure gauges show internal chamber conditions during the cycle.
Thermal fuse (all models) and double pole fuses (not 120v models) protect against overheating and electrical faults.
‘TST’ indicator strips provide independent verification that the correct combination of temperature, steam and time have been achieved for successful sterilization.
For your assurance of quality, each autoclave is computer tested and issued with a unique Performance Test Certificate showing that the parameters for successful sterilization have been met.
Each autoclave is issued with a Certificate of Compliance (not 120v models) stating the pressure vessel conforms to BS3970 Pt.4, as certified independently by Eagle Star.
Model options:
The range of model sizes and internal furniture options ensures the 2100 Classic remains the proven choice for all healthcare professionals throughout the world - whatever their sterilizing needs.
Furniture options:-
General Medical, Dental, Chiropody, Beauty, Tattooing, Body piercing, Veterinary and Laboratory applications.
Chamber options:- 
Standard - 9 litre
Extended - 12 litre 'Media'
Sterilizing options:-
126ºC for 11 minutes or
121ºC for 16 minutes.
230 volt or 120 volt options.
(121ºC option only on certain models,
120v models - 121ºC only)
Accessories
Instrument tray 219293
Instrument basket for Standard Models 219292
Instrument basket for Extended Models 219296
Instrument tray and cassette rack lifter 219294
Instrument basket for Super Extended Models 219509
Dental or small instrument cassette 219291
Cassette rack 219290
Cord Set UK 219258
Euro 219297
UL (American) 219299
Silicone gasket 219500
Basket ‘V’ Support 219295
TST indicator strips 121ºC/15 mins 219276
126ºC/10 mins 219277
Ordering Information:
|
|
Standard |
Extended |
Super Ext' |
||||
|
|
210001 |
210008 |
210003 |
210002 |
|
210007* |
210004 |
|
|
210011 |
210006* |
210012 |
|
|
|
|
|
Chamber capacity: |
9 ltr |
9 ltr |
9 ltr |
12 ltr |
|
12 ltr |
12 ltr |
|
Max width - overall: |
340mm |
340mm |
340mm |
340mm |
|
340mm |
340mm |
|
Max height - overall: |
335mm |
335mm |
335mm |
420mm |
|
420mm |
482mm |
|
Max nett weight: |
4.5Kg |
4.5kg |
4.5Kg |
4.5Kg |
|
4.5kg |
4.5kg |
|
Chamber diameter: |
210mm |
210mm |
210mm |
210mm |
|
210mm |
210mm |
|
Chamber height: |
236mm |
236mm |
236mm |
328mm |
|
328mm |
328mm |
|
Max inst' length: |
228mm |
228mm |
228mm |
290mm |
|
290mm |
290mm |
|
Max load weight: |
3kg |
3kg |
3kg |
4kg |
|
4kg |
4kg |
|
Sterilizing temp': |
126°C |
121°C |
121°C |
126°C |
|
121°C |
126°C |
|
Min sterilizing time: |
11mins |
16mins |
16mins |
11mins |
|
16mins |
11mins |
|
Cycle time - nominal: |
22mins |
26mins |
26mins |
22mins |
|
26mins |
25mins |
|
Operating pressure: |
1.4bar |
1.05bar |
1.05bar |
1.4bar |
|
1.05bar |
1.4bar |
|
Voltage: |
230v |
230v |
120v |
230v |
|
120v |
230v* |
|
Wattage: |
1500w |
1500w |
1200w |
1500w |
|
1200w |
1500w* |
|
Frequency: |
50-60Hz |
50-60Hz |
50-60Hz |
50-60Hz |
|
50-60Hz |
50-60Hz |
|
*210006 - 120v/1200w |
|||||||
Omega autoclaves
Omega autoclaves employ a process referred to as upward displacement - as pressurised steam is generated within the vessel, air is forced up and out, allowing steam to come into contact with all instrument surfaces, destroying harmful bacteria and spores.
Model specifications:
- Touch sensitive control and display panel for quick and easy use
- Fully automatic sterilising cycles
- Capacity: 10 litres
- External dimensions: 420H x 350W mm.
- Internal dimensions: 210 dia. x 270H mm.
- Max. load weight: 4.0 Kg.
- Weight: 9.2 Kg.
Model options:
- Omega Uniclave - 134oC / 3.5 minute cycle
- Omega 121/134 - 121oC / 16 minute and 1340C / 3.5 minute cycles
- Omega Media - 121oC / 22 minute cycle for media (lid will not open until temperature drops below 80oC)
- Omega CJD - 134oC / 18 minute cycle
Zenith autoclaves
The ultimate vacuum handpiece autoclave
" Vacuum autoclaves are the method of choice for sterilising wrapped and hollow instruments" - 'Infection control in dentistry - proceedings of the British Dental Association workshop' February 2002
The Zenith is unique - a fully specified Type 'B' autoclave which has been designed specifically for the rapid sterilisation of complex, hollow instruments, including dental handpieces.
Versatile loads:
- Stainless steel holder can be easily configured for sterilising pouched or unpouched instruments and provides capacity to sterilise up to 10 pouched handpieces
- Self-sealing instrument pouches with sterilisation indicators are available in 2 sizes
- Two, large capacity baskets enable unpouched items to be sterilised
- Vertical chamber allows full use to be made of its 2.5 litre capacity
Single use water system:
- Uses clean, uncontaminated water for each cycle
- Fully accessible reservoir is easy to refill
- Only the required volume of water is used for each cycle
- 0.75 litre reservoir of fresh water is sufficient for 10 cycles
- Used water container easily removed for emptying
- Fail safe mechanism indicates when water container requires emptying
Features:
- Triple pulsed fractionated vacuum cycle - ensures more effective air removal allowing all loads to be sterilised safely and effectively
- Bowie Dick & Helix steam penetration tests - gives peace of mind knowing that the autoclave continues to operate effectively at all times
- Single shot water system - prevents the build-up of contaminants within the reservoir, allowing for easy cleaning and a more hygienic starting point for each sterilisation cycle
- Automatic air leakage detection test - ensures that if there is a problem with the vacuum system, the sterilisation cycle will not operate
- The touch sensitive control panel with LCD display has been designed to be as simple to use as possible. The selection, acceptance and commencement of the preferred cycle is done simply at the press of a button
- Six automatic cycles:
1. 134oC / 18 minute cycle 2. 134oC / 3 minute Type B vacuum cycle for linen loads, wrapped, pouched or unpouched instruments, with drying 3. 134oC / 3 minute vacuum cycle for unpouched solid or hollow instruments, with drying 4. 1340C / 3 minute cycle for unpouched solid or hollow instruments without drying
5. non-vacuum cycle for unpouched instruments, with drying 6. non-vacuum cycle for unpouched instruments, without drying
Specifications:
- Chamber capacity: 2.5 litres
- Overall dimensions: 270 mm. wide; 355 mm. deep; 360 mm. high (lid closed); 525 mm. high (lid open); 700 mm. high (required for instruments holder removal)
- Weight: 12.4 Kg.
- Chamber dimensions: 110 mm. diameter; 254 mm. deep; 210 mm. deep (unpouched instruments) or 175 mm. deep (pouched instruments)
- Max. instrument length: 210 mm.
- Porous load size: 150 x 75 x 38 mm.
- Max. instrument load (pouched or unpouched): 1 Kg.
- Sterilising cycles: 134oC / 3 minutes or 134oC / 18 minutes
- Operating pressure: 2.05 bar
- Electrical: 230V / 2200W / 50Hz
- Optional printer provides a permanent record of all cycles
Century 3 autoclave
The Century 3 Advance autoclave provides the most effective and affordable means available for complying with all the guidelines for instrument sterilisation. It is designed to comply with the following standards:
- Medical Devices Directive (93/42/EEC)
- E.M.C.Directive (89/336/EEC)
- EN13060
- Pressure vessel to ASME Section VIII
- BS EN 610100 Parts 1 & 2
Features:
- Vacuum and non-vacuum models
- 16 and 22 litre capacity
- Triple pulsed fractionated vacuum cycle - ensures more effective air removal allowing all loads to be sterilised safely and effectively
- Bowie Dick & Helix steam penetration tests - gives peace of mind knowing that the autoclave continues to operate effectively at all times
- Single shot water system - prevents the build-up of contaminants within the reservoir, allowing for easy cleaning and a more hygienic starting point for each sterilisation cycle
- Automatic air leakage detection test - ensures that if there is a problem with the vacuum system, the sterilisation cycle will not operate
- Unique door design - touch of a button to open and can be pushed closed just as easily
- The touch sensitive control panel is simple to operate - the press of a button selects the cycle, another starts it
- Optional printer module provides a permanent record of all cycles
- Six automatic cycles:
1. vacuum cycle for linen loads, wrapped, pouched or unpouched instruments with drying
2. vacuum cycle 134oC / 18 minutes
3. rapid vacuum cycle (14 minutes total cycle time) for unpouched solid or hollow instruments without drying
4. vacuum cycle for Steam Penetration Test
5. non-vacuum cycle for unpouched instruments, with drying 134oC
6. non-vacuum cycle for unpouched instruments, without drying 1210C
Specifications:
|
Chamber capacities |
16 litre |
22 litre |
|
Overall width |
480 mm. |
480 mm. |
|
Overall height |
410 mm. |
410 mm. |
|
Overall length |
440 mm. |
560 mm. |
|
Weight |
42 Kg. |
43 Kg. |
|
Chamber diameter |
250 mm. |
250 mm. |
|
Chamber length |
330 mm. |
430 mm. |
|
Tray/rack capacity/length* * config. model specific |
6 @ 282 mm. |
6 @ 430 mm. |
|
Max. instrument length |
300 mm. |
450 mm. |
|
Max. load, non-vacuum Max. load, vacuum |
2 Kg. (unpouched) 6 Kg. (unpouched) 2 Kg. (pouched) 1 Kg.* (porous) * pack size 150x120x100 mm. |
6 Kg. (unpouched) 6 Kg. (unpouched) 2 Kg. (pouched) 1 Kg.* (porous) |
|
Sterilising temp./time, non-vacuum Sterilising temp./time, vacuum |
134oC / 4 minutes |
134oC / 4 minutes |
|
Operating pressure (min.) |
2.05 bar |
2.05 bar |
|
Electrical |
230V / 2200W / 50-60Hz |
230V / 2200W / 50-60Hz |
Century3 Advance vacuum autoclave
The Century 3 Advance is designed to comply with the same standards as the Century 3 models but also complies with:
Features:
Similar to Century 3 but Century 3 Advance is only available in a vacuum model and also available with optional data logger and computer analysis modules as well as the printer module to provide 3 methods to permanently record all cycles
Specifications:
|
Chamber capacities |
16 litre |
22 litre |
|
Overall width |
480 mm. |
480 mm. |
|
Overall height |
410 mm. |
410 mm. |
|
Overall length |
440 mm. |
560 mm. |
|
Weight |
35 Kg. |
37 Kg. |
|
Chamber diameter |
250 mm. |
250 mm. |
|
Chamber length |
330 mm. |
430 mm. |
|
Tray/rack capacity/length* * config. model specific |
6 @ 282 mm. |
4 @ 282 mm. plus 2 @ 98 mm. |
|
Max. instrument length |
300 mm. |
450 mm. |
|
Operating pressure (min.) |
2.05 bar |
2.05 bar |
|
Electrical |
230V / 2200W / 50-60Hz |
230V / 2200W / 50-60Hz |