Thermomixers
Progen Scientific offer ThermoMixers with the traditional orbital shaking motion. They are specially used when in tapered test tubes critical DNA pellets shall be worked out of the conic top to get into solution. For one changeable insert block for micro test tubes, test tubes, centrifugal tubes, cuvettes or PCR-plates, microtiter or Deep-Well plates. With timer, short-mix-function, interval shaking with shock effect.
Favor Thermal Shaker Single Block Dry Bath Incubator
Features:
- Microprocessor controlled with digital display
- Microprocessor controls incubation time, shaking speed and temperature
- The block, designed by tube shape, is easy to heat uniformly
- 8 interchangeable blocks to choose from (0.2ml. to 50ml. tubes)
- Digital performance at analogue prices
- Fast and accurate heating by P.I.D. controller
- Temperature range from ambient +5°C to +100°C in 0.1°C increments
- LCD monitor
- User calibration
- Over heating protection device ensures safety and reliability
- Over high temperature alarm and over low temperature alarm
- Beep signal and stop after programme completion
Specifications:
|
Controller
|
Digital microprocessor controller
|
|
Display
|
20 x 2 LCD
|
|
Temperature control range
|
Ambient +5°C to +100°C
|
|
Temperature increments
|
0.1°C
|
|
Temperature calibration
|
Yes
|
|
Temperature uniformity
|
± 0.3°C
|
|
Temperature accuracy
|
± 0.2°C
|
|
Heating time
|
from 20°C to 100°C: 12 minutes
|
|
Shaking speed range
|
100 – 1200 rpm. in 1 rpm. increments
|
|
Shaking orbit
|
2 mm.
|
|
Operation mode
|
Constant operation: Constant temperature (from ambient +5°C to +100°C; Timer: 0 to 99 hours 59 minutes
|
|
Data log
|
No
|
|
Safety device
|
Leakage proof for heating chamber
|
|
Heating chamber material
|
Plastics
|
|
Block material
|
Aluminium
|
|
Rated voltages
|
110V / 220V selectable
|
|
Dimensions
|
212W x 300D x 180H mm.
|
|
Weight
|
5.0 kg.
|
Ordering information:
|
Cat. number
|
Description
|
|
FATSM 001
|
Favor Thermal Shaker Single Block Dry Bath Incubator
|
|
Blocks
|
|
|
FATSM-A
|
Block A: 96 x 0.2ml. tubes with lid
|
|
FATSM-B
|
Block B: 54 x 0.5ml. tubes with lid
|
|
FATSM-C
|
Block C: 35 x 1.5ml. tubes with lid
|
|
FATSM-D
|
Block D: 35 x 2.0ml. tubes with lid
|
|
FATSM-E
|
Block E: 15 x 0.5ml. + 20 x 1.5ml. tubes with lid
|
|
FATSM-F
|
Block F: 24 x ≤ diameter 12 mm. tubes
|
|
FATSM-G
|
Block G: 12 x 15ml. Falcon tubes
|
|
FATSM-H
|
Block H: 6 x 50ml. Falcon tubes
|
Favor Cooling-Heating Thermal Shaker Single Block Dry Bath Incubator
Features:
- Microprocessor controlled with digital display
- Microprocessor controls incubation time, shaking speed and temperature
- The block, designed by tube shape, is easy to heat uniformly
- 8 interchangeable blocks to choose from (0.2ml. to 50ml. tubes)
- Digital performance at analogue prices
- Fast and accurate heating by P.I.D. controller
- Temperature range from ambient -10°C to +100°C in 0.1°C increments
- LCD monitor
- User calibration
- Over heating protection device ensures safety and reliability
- Over high temperature alarm and over low temperature alarm
- Beep signal and stop after programme completion
Specifications:
|
Controller
|
Digital microprocessor controller
|
|
Display
|
20 x 2 LCD
|
|
Temperature control range
|
0°C to +100°C
|
|
Temperature increments
|
0.1°C
|
|
Temperature calibration
|
Yes
|
|
Temperature uniformity
|
± 0.3°C
|
|
Temperature accuracy
|
± 0.5°C
|
|
Heating time
|
from 20°C to 100°C: ~ 0.6°C per minute
|
|
Cooling time
|
from ambient to ambient -10°C: ≤ 12 minutes
from 100°C to ambient +10°C: ≤ 15 minutes
|
|
Shaking speed range
|
200 – 1500 rpm. in 1 rpm. increments
|
|
Shaking orbit
|
2 mm.
|
|
Operation mode
|
Constant operation: Constant temperature (from ambient +5°C to +100°C; Timer: 0 to 99 hours 59 minutes
|
|
Data log
|
No
|
|
Safety device
|
Leakage proof for heating chamber
|
|
Heating chamber material
|
Plastics
|
|
Block material
|
Aluminium
|
|
Rated voltages
|
110V / 220V selectable
|
|
Dimensions
|
212W x 300D x 180H mm.
|
|
Weight
|
8 kg.
|
Ordering information:
|
Cat. number
|
Description
|
|
FATSM 002
|
Favor Cooling-Heating Thermal Shaker Single Block Dry Bath Incubator
|
|
Blocks
|
|
|
FATSM-A
|
Block A: 96 x 0.2ml. tubes with lid (max. speed 1500 rpm.)
|
|
FATSM-B
|
Block B: 54 x 0.5ml. tubes with lid (max. speed 1500 rpm.)
|
|
FATSM-C
|
Block C: 35 x 1.5ml. tubes with lid (max. speed 1500 rpm.)
|
|
FATSM-D
|
Block D: 35 x 2.0ml. tubes with lid (max. speed 1500 rpm.)
|
|
FATSM-E
|
Block E: 15 x 0.5ml. + 20 x 1.5ml. tubes with lid (max. speed 1500 rpm.)
|
|
FATSM-F
|
Block F: 24 x ≤ diameter 12 mm. tubes (max. speed 1200 rpm.)
|
|
FATSM-G
|
Block G: 12 x 15ml. Falcon tubes (max. speed 750 rpm.)
|
|
FATSM-H
|
Block H: 6 x 50ml. Falcon tubes (max. speed 750 rpm.)
|
HLC Thermomixers
HLC offers 2 different Controls:
- The Economy Control 1 with Timer,
- The comfortable, programmable Control 3 for 30 program steps, temperature curves, with USB interface as standard.
The microprocessor control with new, self-optimising digital controller guarantees, even at extreme temperatures a high temperature accuracy +/- 0.1° C for both controls 1 and 3.
The new, variable and future-oriented Operation System S 03 of HLC:
Units with Control 3 can be used in different ways:
- with plugged operation unit BT 03
- with cable connection (up to 10 m) between BT 03 and a Mixer or Thermostat
- without operation unit, with a set program
- with a computer
- with a process card with individual stored process data.
- The comfortable, programmable Control 3 for 30 program steps, temperature curves, with USB interface as standard.
The microprocessor control with new, self-optimising digital controller guarantees, even at extreme temperatures a high temperature accuracy +/- 0.1° C for both controls 1 and 3.
The new, variable and future-oriented Operation System S 03 of HLC:
Units with Control 3 can be used in different ways:
- with plugged operation unit BT 03
- with cable connection (up to 10 m) between BT 03 and a Mixer or Thermostat
- without operation unit, with a set program
- with a computer
- with a process card with individual stored process data.
Heating Thermomixer MHR11, orbital shaking motion, for one thermoblock, with Control 1
The economy thermomixer with optimized microprocessor Control 1
Fast for heating and mixing
Precise and even ± 0.1°C, ambient +3°C (+23°C) to +130°C
For one exchangeable thermoblock
Slender, 160 mm. wide
Stirring speed range: 200 – 1500 rpm.
Heating Thermomixer MHR13, orbital shaking motion, for one thermoblock, with Control BT03
Fast for heating and mixing
Precise and even ± 0.1°C, ambient +3°C (+23°C) to +130°C
For one exchangeable thermoblock
Short mix function, interval shaking
Programmable: 30 programme steps
Stirring speed range: 200 – 1500 rpm
Heating Thermomixer MHR23, orbital shaking motion, for 2 thermoblocks, with Control BT03
Fast for heating and mixing
Precise and even ± 0.1°C, ambient +3°C (+23°C) to +130°C
For one exchangeable thermoblock
Short mix function, interval shaking
Programmable: 30 programme steps
Stirring speed range: 200 – 1500 rpm
Space saving slender, 220 mm. wide
Heating Thermomixer MHL23, reciprocal shaking motion, for 2 thermoblcoks, with Control BT03
Fast for heating and mixing
Precise and even ± 0.1°C, ambient +3°C (+23°C) to +130°C
For two exchangeable thermoblocks
Short mix function, interval shaking
Programmable: 30 programme steps
Stirring speed range: 200 – 1300 rpm
Space saving slender, 220 mm. wide
The Cool Single:
Cooling Thermomixer MKR13, orbital shaking motion, for one thermoblock, with Control BT03
Fast for cooling or heating
Ambient -16°C (+4°C) to +100°C
Counter-cooling with Peltier elements
Precise ± 0.1°C
For one exchangeable thermoblock
Stirring speed range: 200 – 1500 rpm.
Programmable: 30 programme steps
The Cool Double:
Cooling Thermomixer MKR23, orbital shaking motion, for 2 thermoblocks, with Control BT03
Fast for cooling or heating
Ambient -6°C (+10°C) to +70°C
Counter-cooling with Peltier elements
Precise ± 0.5°C
For two exchangeable thermoblocks
Stirring speed range: 200 – 1500 rpm.
Programmable: 30 programme steps
Ordering information:
|
Model
|
Description
|
Mixing motion
|
Temp. range
|
Mixing speed
|
|
MKR13
|
Cooling-ThermoMixer with BT 03
|
orbital
|
Amb. -16°C ... +100°C
|
200 - 1.500 1/min
|
|
MKR23
|
Cooling-ThermoMixer with BT 03
|
orbital
|
Amb. -10°C ... +70°C
|
200 - 1.200 1/min
|
|
MHR13
|
Heating-ThermoMixer with BT 03
|
orbital
|
Amb. +3°C ... +130°C
|
200 - 1.500 1/min
|
|
MHR23
|
Heating-ThermoMixer with BT 03
|
orbital
|
Amb. +3°C ... +130°C
|
200 - 1.500 1/min
|
|
MHR11
|
Heating-ThermoMixer with Control 1
|
orbital
|
Amb. +3°C ... +130°C
|
200 - 1.500 1/min
|
|
MHL23
|
Heating-ThermoMixer with BT 03
|
reciprocal
|
Amb. +3°C ... +130°C
|
200 - 1.300 1/min
|
Exchangeable thermoblocks for all Thermomixers:
|
Model
|
Description
|
L x W x H mm.
|
|
Thermoblocks for
microtubes
|
|
|
|
BM02
|
92 x 0.2ml. tapered
|
128 x 85 x 37.5
|
|
BM05
|
24 x 0.5ml. tapered
|
128 x 85 x 37.5
|
|
BM15
|
24 x 1.5ml. tapered
|
128 x 85 x 37.5
|
|
BM20
|
24 x 2.0ml. parallel
|
128 x 85 x 37.5
|
|
Thermoblocks for test tubes
|
|
|
|
BP10
|
24 x 10 mm.
|
128 x 85 x 47.5
|
|
BP12
|
24 x 12 mm.
|
128 x 85 x 47.5
|
|
BP15
|
24 x 15 mm.
|
128 x 85 x 47.5
|
|
BP16
|
24 x 16 mm.
|
128 x 85 x 47.5
|
|
BZ15
|
14 x 15 ml. Falcon
|
128 x 85 x 47.5
|
|
BZ50
|
6 x 50 ml. Falcon
|
128 x 85 x 47.5
|
|
Thermoblocks for PCR plates
|
|
|
|
BC96
|
96 x ‘V’ bottom, 0.2ml.
|
128 x 85 x 47.5
|
|
BC84
|
384 x PCR
|
128 x 85 x 47.5
|
|
Thermoblocks for microplates
|
|
|
|
BV96
|
96 x round or ‘V’ bottom
|
128 x 85 x 44.5
|
|
BF96
|
96 flat bottom
|
128 x 85 x 44.5
|
|
BD96
|
96 x round or ‘V’ bottom deep well
|
128 x 85 x 44.5
|
|
Other thermoblocks
|
|
|
|
BN10
|
For 36 x rectangular cuvettes, 12.5 mm. outside
|
128 x 85 x 37.5
|
|
B037
|
Undrilled block
|
128 x 85 x 37.5
|
|
BO50
|
Undrilled block
|
128 x 85 x 47.5
|
|
BY12
|
Hybridisation block for 12 slides, 75-77W x 25-26D x 0.8-1.5H mm.
|
|
|
BW01
|
Thermoblock as tempering tub for deep-well plates or other tubes, 128 x 15 mm.
|
|
|
BI01
|
Cover for block insulation
|
|
Accessories for Thermomixers:
|
BR02
|
Stacking rack and stand, tubes 0.2ml.
|
|
BR05
|
Stacking rack and stand, 0.5ml.
|
|
BR15
|
Stacking rack and stand, 1.5/2.0ml.
|
|
BK02
|
Cooling box for tubes 0.2ml. and PCR plates 96 x ‘V’
|
|
BK05
|
Cooling box for tubes 0.5ml.
|
|
BK15
|
Cooling box for tubes 1.5 or 2.0ml.
|
|
BT01
|
Tempering / anti-condensate head-piece, transparent, for 1 block
|
|
BT02
|
Tempering / anti-condensate head-piece, transparent, for 2 blocks
|
|
BA24
|
Anti-condensate plate for 1 thermoblock for micro test tubes
|
|
BA96
|
Anti-condensate plate for1 thermoblock for test plates
|
|
BH10
|
Heating top for use with cooling units
|
| Call... | Enquire... |
|---|---|
| Call Progen Scientific to discuss your requirements on 0845 430 8555 | Click here to make an enquiry online |