Kern Moisture Analysers
Kern MLB 50-3 Moisture Analyser
Features:
- 2 halogen quartz glass heaters (200 W each)
- Heating temperature range: 50 - 160oC in 0.1oC increments
- Weighing range: max. sample weight 50 g.
- Read-out: 0.001 g. or 0.01%
- 3 displays: temperature; drying in %; drying time
- Switch off criteria: 1. when the set time has expired (10 min. - 9 h. 50 min.)
2. when constant weight per adjustable time unit has
been achieved 1 - 59 seconds)
Dry mass (%) = residual weight of starting weight (100 - 0%)
Loss in weight / final weight x 100% (0 - 999%)
NOTE: Display can be switched between the above 3 displays at any time
(only in combination with Kern printer YKB-01 or PC)
- Last measured value remains in display until replaced by a new measurement
- Application table with many practical examples in the operating instructions
- 10 aluminium sample plates 92 mm. dia.provided (also MLB-A01, pack of 80)
- Calibration by external weight (not supplied)
- RS232 C data interface for connection to PC or printer
- Mains adaptor (supplied)
- 3 year warranty
Specifications:
|
Model |
Weighing range g. |
Readability |
Heating temp. range |
|
MLB 50-3 |
50 |
0.001g. or 0.01% |
50 - 160oC |
Accessories:
|
Cat. Number |
Description |
|
YKB-01 |
Standard printer |
|
MLB-A01 |
Aluminium sample plates 92 mm. dia. (pack of 80) |
|
MLB-A03 |
Calibration set consisting of measurement sensor and display |
|
RH-A02 |
Round fibreglass filter e.g. for samples that splash or become encrusted (pack of 100) |
Kern MLS 50-3 Moisture Analyser
Features:
- 2 halogen quartz glass heaters (200 W each)
- Heating temperature range: 50 - 160oC in 0.1oC increments
4 drying methods: standard, gradual, stage or preheating stage
- Weighing range: max. sample weight 50 g.
- LCD graphic display, back-lit: 1. display in moisture %
2. momentary moisture proportion in %
3. print interval 30 seconds
4. print edition in moisture %
5. switch-off mode
6. drying method standard
7. drying time up to now
8. status bar
9. present temperature
10. drying method standard
11. target temperature
12. drying process active
- 3 displays: temperature; drying in %; drying time
- Switch off criteria: 1. when the set time has expired (10 min. - 9 h. 50 min.)
2. when loss in weight per unit of time falls below the target
value, both values freely adjustable (mg. / second)
Dry mass (%) = residual weight of starting weight (100 - 0%)
Loss in weight / final weight x 100% (0 - 999%)
Residual weight (absolute value in g.)
NOTE: Display can be switched between the above 4 displays at any time
(only in combination with Kern printer YKB-01 or PC)
- Last measured value remains in display until replaced by a new measurement
- Application table with many practical examples in the operating instructions
- 10 aluminium sample plates 92 mm. dia.provided (also MLB-A01, pack of 80)
- Calibration by external weight (not supplied)
- RS232 C data interface for connection to PC or printer
- GLP/ISO record keeping on ARJ models (only with printer YKB-01)
- Balance contains memory for automatic sequence of 99 complete drying processes.
Per memory location 12 free characters
- 'Weighing-in' help to a defined target value (g.) with adjustable tolerance range 1% - 25% of target value
- Simple step by step user guidance in the display
- Internal clock for date and time
- PC keyboard can be connected
- Mains adaptor (supplied)
- 3 year warranty
Specifications:
|
Model |
Weighing range g. |
Readability |
Heating temp. range |
|
MLS 50-3 |
50 |
0.001g. or 0.01% |
50 - 160oC |
Accessories:
|
Cat. Number |
Description |
|
YKB-01 |
Standard printer |
|
MLB-A01 |
Aluminium sample plates 92 mm. dia. (pack of 80) |
|
MLB-A03 |
Temperature calibration set consisting of measurement sensor and display |
|
RH-A02 |
Round fibreglass filter e.g. for samples that splash or become encrusted (pack of 100) |
Kern MRS 120-3 Moisture Analyser
Features:
- Halogen quartz glass heater 400 W
- Heating temperature range: 30 - 230oC in 1oC increments
3 drying methods: standard, gradual (final temp. achieved after 4 min.)
or preheating stage (0.1 - 99 min.)
- Weighing range: max. sample weight 124 g.
- Read-out: 0.001 g. or 0.01%
- 4 displays: results in g or %; temperature; heating mode; temperature and time
- Switch off criteria: 1. when the set time has expired (0.1 - 240 min.)
2. when constant weight has been achieved
3. when loss in weight per unit of time falls below the target value,
both values freely adjustable (g. / min.) or (% / min.)
4. weight loss (abs. value in g.)
5. residual weight (abs. value in g.)
Dry mass (%) = residual weight of starting weight (100 - 0%)
Loss in weight / final weight x 100% (0 - 999%)
NOTE: Display can be switched between the above 3 displays at any time
- 4 displays for results in g. or %, heating mode, temperature and time
- Measured value monitoring: Interval adjustable from 0.1 - 10 minutes with automatic
number sampling (only in combination with Kern printer YKB-01 or PC)
- Calibration by external weight (not supplied)
- Last measured value remains in display until replaced by a new measurement
- Application table with many practical examples in the operating instructions
- 30 aluminium sample plates 92 mm. dia.provided (also MLB-A01, pack of 80)
- Calibration by external weight (not supplied)
- RS232 C data interface for connection to PC or printer
- GLP/ISO record keeping on ARJ models (only with printer YKB-01)
- Balance contains memory for automatic sequence of 5 complete drying processes.
- 'Weighing-in' help to a defined target value (g.) with adjustable tolerance range
- Simple step by step user guidance in the display
- Internal clock for date and time
- Mains adaptor (supplied)
- Sight window over the sample is extremely useful during initial adjustment
- Protective working cover over the keypad (replaceable as PR-A25 )
- 3 year warranty
Specifications:
|
Model |
Weighing range g. |
Readability |
Heating temp. range |
|
MRS 120-3 |
124 |
0.001g. or 0.01% |
30 - 230oC |
Accessories:
|
Cat. Number |
Description |
|
YKB-01 |
Standard printer |
|
MLB-A01 |
Aluminium sample plates 92 mm. dia. (pack of 80) |
|
MRS-A01 |
Temperature calibration set consisting of calibration plate with measurement sensor and evaluation box |
|
RH-A02 |
Round fibreglass filter e.g. for samples that splash or become encrusted (pack of 100) |